Battery

Removal
CAUTION:
A lithium battery can cause fire, explosion, or severe burn. Do not recharge, disassemble, heat
above 100°C (212°F), solder directly to the cell, incinerate, or expose cell contents to water. Keep
away from children. Replace only with the part number specified for your system. Use of another
battery may present a risk of fire or explosion.
The battery connector is polarized; do not attempt to reverse polarity.
Dispose of the battery according to local regulations.
1. Place the I/O drawer in the rear service position, as described in "Rear Service Position" on page 463.
2. Remove the two thumbscrews and remove the back top cover.
3. Locate the battery on the PCI board.
Battery
Socket
Chapter 10. Removal and Replacement Procedures
465