Map 1522: Cannot Power On the CEC Drawer

Step 1522-1
Attempt to power on the CEC drawer (see "Powering Off and Powering On the System" on page 415).
Does the CEC drawer power on?
NO
Go to "Step 1522-2."
This ends the procedure. Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver
YES
pSeries Diagnostic Information for Multiple Bus Systems.
Step 1522-2
Look at the power supply LEDs at the back of the CEC drawer.
Is there a power supply with a flashing LED?
NO
Go to "Step 1522-3."
YES
Replace the power supply with the flashing LED.
This ends the procedure. Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver
pSeries Diagnostic Information for Multiple Bus Systems.
Step 1522-3
Are all SPCN cables seated firmly and connected correctly between the primary I/O drawer,
secondary I/O drawers and CEC drawer?
NO
Fix the SPCN cable connections
This ends the procedure. Go to "MAP 0410: Repair Checkout" in the RS/6000 and Eserver
pSeries Diagnostic Information for Multiple Bus Systems.
YES
Go to "Step 1522-4."
Step 1522-4
Is this machine connected to dc power?
NO
Go to "Step 1522-8" on page 93.
YES
Go to "Step 1522-5" on page 93.