Furuno GP-150 Installation Manual page 105

Marine gps navigator
Hide thumbs Also See for GP-150:
Table of Contents

Advertisement

3) Press
or
to select NMEA 0183
(V1.5 or V2.0) or IEC 61162-1.
4) Press the NU/CU ENT key. Talker ID
appears in reverse video.
5) Press
or
to select GP, LC or DE.
6) Press the NU/CU ENT key.
7) Enter Tx interval for each output data
sentence in line 1. Tx interval is available
in 00, 01, 02, 03, 04, 05, 06, 10, 15, 20,
30, 60 and 90 (seconds).
8) Press the NU/CU ENT key.
9) Enter Tx interval for each output data
sentence in lines 2 through 5. Press the
NU/CU ENT key after setting each line.
For detailed information about Tx interval
see the installation manual. However, the
settings entered by the installer of the
equipment should not be changed unless
absolutely necessary.
BWC is for great circle navigation; BWR is
for rhumb line navigation.
The total data output are shown by
percentage on the third line. For best results
the total output should not exceed 90%;
lengthen the Tx interval of less important
data to make the total output less than 90%.
When the external equipment cannot display
correct data input from the GP-150, the rate
of operation should be lowered.
For example, set a rate of operation less
then 60% for the Temperature Indicator
TI-20.
DATA 2 output setting
1) Press MENU ESC, 9 and 4. The DATA 2
OUTPUT SETUP menu appears.
DATA 2 OUTPUT SETUP
Data Fmt.
Talker ID
GP
Output Data
(00-90 sec)98%
1. AAM:00 APA:00
2. BWR:00 BWW:00 GGA:00 GLL:01
3. RMB:01 RMC:00
4. VDR:00 WPL:00
5. GNS:00 GBS:01
: Select
ENT : Enter
Settings shown here are default settings.
Figure 8-9 DATA 2 OUTPUT
SETUP menu
2) Follow the procedure for setting DATA 1
output.
DATA 3 output setting
The DATA 3 connector can output IEC
61162-1/NMEA 0183 data or log pulse. (For
details, see the Installation Manual.) For
NMEA 0183, IEC 61162-1 the same data
output by DATA 1 is output from DATA 3.
For log pulse, select 200 or 400 pulse per
second depending on the device connected.
1) Press MENU ESC, 9 and 3.
2) Press
or
to select DATA 3. Log
Pulse.
3) Press
or
to select log pulse of
external equipment; 200ppm or 400ppm.
4) Press the NU/CU ENT key twice.
8. MENU SETTINGS
V1.5
V2.0
IEC
LC
DE
APB:04
BOD:00
VTG:01 WCV:00
XTE:00
ZDA:01
Rnn:00
RTE:00
MENU : Escape
8-7