No Ice Dispense In Manual Mode - Cornelius IDC 255 PROGATE DRIVE THRU UNIT Installation Manual

Hide thumbs Also See for IDC 255 PROGATE DRIVE THRU UNIT:
Table of Contents

Advertisement

N
I
D
O
CE
ISPENSE IN
NO ICE DISPENSE IN MANUAL
Is manual/
automatic rocker switch
in the manual position
1. Set the machine to manual
mode by pressing the manual
/automatic rocker switch
Do drink valves
operate
No
1. Check key lock out switch
2. Check transformer for power
3. Check all connections from
the terminal board to the
push button
© 2006-2014, Cornelius Inc.
M
M
ANUAL
ODE
MODE
pressure greater
Yes
No
No
1. Check the connector
Yes
between the control
box and the E - Box
Is ice being
dispensed in
auto mode
No
Is Ice chute
switch enabled or
disabled
Disabled
1. Check magnetic switch in switch housing
2. Check for magnet in ice chute cover
3. Validate magnet distance from magnetic switch
for activation to occur
4. Check ice chute disable switch ensuring that relay 1 is
activating
5. Check transformer outputs wiring
IDC 255 Progate Drive Thru Installation Manual
1. Check the connector between the
Is the
control box and the E-Box.
machine inlet
Yes
2. Check relay 3 in the E-Box for power
(terminal 3&4).
than 35 PSI
3. Check pneumatic solenoid.
No
1. Check air supply shut off outside the E-Box
2. Check air supply line
3. Check pneumatic cylinder for free movement
Yes
Is lighted green push
Yes
button on
No
Does the agitator run
when push button is
pressed
No
1. Check the red LED on the
E - Box board
2. Ensure that relay two in the
E-Box is activating
1. Check relay 1 in the E-Box.
Enabled
The small post on the right hand
side should be retracted
- 29 -
Is ice
present in the
ice chute
1. Check the electrical
connection from the
portion control board to
the solenoid valve
2. Check pneumatic solenoid
3. Check relief valve
Publication Number: 621057419INS