Agitation Time - Cornelius IDC 255 PROGATE DRIVE THRU UNIT Installation Manual

Hide thumbs Also See for IDC 255 PROGATE DRIVE THRU UNIT:
Table of Contents

Advertisement

IDC 255 Progate Drive Thru Installation Manual

Agitation Time

The software coding for the progate system involves a direct relationship between the dispense time and the agitation
time.
The relationship is expressed below.
Agitation Time (A
) = Dispense Time (D
T
Publication Number: 621057419INS
Dispense
Agitation
Rime (mS)
Ratio
50
10
70
10
90
10
110
10
130
10
150
10
170
10
190
10
210
10
230
10
Dispense
Agitation
Rime (mS)
Ratio
50
16
70
16
90
16
110
16
130
16
150
16
170
16
190
16
210
16
230
16
Dispense
Agitation
Rime (mS)
Ratio
50
28
70
28
90
28
110
28
130
28
150
28
170
28
190
28
210
28
230
28
2 2
) x Agitation Ratio
(R
T
- 18 -
Agitation
Time (mS)
500
700
900
1100
1300
1500
1700
1900
2100
2300
Agitation
Time (mS)
800
1120
1440
1760
2080
2400
2720
3040
3360
3680
Agitation
Time (mS)
1400
1960
2520
3080
3640
4200
4760
5320
5880
6440
)
A
© 2006-2014, Cornelius Inc.