Flat Drinks - Cornelius IDC 255 PROGATE DRIVE THRU UNIT Installation Manual

Hide thumbs Also See for IDC 255 PROGATE DRIVE THRU UNIT:
Table of Contents

Advertisement

IDC 255 Progate Drive Thru Installation Manual
F
D
LAT
RINKS
FLAT DRINK(S)
Is the
drink temperature
above 40 degrees
Fahrenheit
No
Is there
ice on the cold
plate
No
1. Fill the hopper with ice.
2. Dispense some ice to
ensure that the agitator
spreads ice on the cold
plate.
Publication Number: 621057419INS
Is CO
2
being supplied to
Yes
the carbonator tank
No
1. Check CO2 supply tank.
2. Check CO2 supply lines.
3. Change CO2 tank
1. Check ice coverage
Yes
on the cold plate
Is the
Yes
CO
pressure in
2
the system
correct
No
1. Adjust CO2 pressure
accordingly
- 32 -
Yes
Replace
carbonator
pump
Does
the carbonator
cycle when a 20oz
Yes
drink is dispensed
No
Refer to
carbonator ow
chart.
© 2006-2014, Cornelius Inc.