IDC 255 Progate Drive Thru Service Manual
N
I
D
O
CE
ISPENSE IN
NO ICE DISPENSE IN MANUAL
MODE
Is manual/
automatic rocker switch
in the manual position
No
Set the machine to manual mode
by pressing the manual/automatic
rocker switch
Do drink valves
operate
No
1. Check key lock out switch
2. Check transformer for power
3. Check all connections from
the terminal board to the
push button
1. Check magnetic switch in switch housing
2. Check for magnet in ice chute cover
3. Validate magnet distance from magnetic switch
4. Check ice chute disable switch ensuring that relay 1 is
5. Check transformer outputs wiring
Publication Number: 621057419SER
M
M
ANUAL
ODE
machine inlet
pressure greater
than 35 PSI
Is lighted green push
Yes
No
Check the connector
Yes
between the control box
and the E - Box
Is ice being
dispensed in
auto mode
No
Is Ice chute
switch enabled or
disabled
Disabled
for activation to occur
activating
1. Check the connector between the
Is the
control box and the E-Box.
Yes
2. Check relay 3 in the E-Box for power
(terminal 3&4).
3. Check pneumatic solenoid.
No
1. Check air supply shut off outside the E-Box
2. Check air supply line
3. Check pneumatic cylinder for free movement
Yes
Yes
button on
No
Does the agitator run
when push button is
pressed
No
1. Check the red LED on the
E - Box board
2. Ensure that relay two in the
E-Box is activating
Check relay 1 in the E-Box. The small
Enabled
post on the right hand side should be
retracted
- 28 -
Is ice
present in the
ice chute
1. Check the electrical
connection from the
portion control board to
the solenoid valve
2. Check pneumatic solenoid
3. Check relief valve
© 2006-2013, IMI Cornelius Inc.