Gigabyte GS-SR 222 Installation Manual

Rack mount server system

Advertisement

Quick Links

GS-SR 222
Rack Mount Server
System
Installation Guide

Advertisement

Table of Contents
loading

Summary of Contents for Gigabyte GS-SR 222

  • Page 1 GS-SR 222 Rack Mount Server System Installation Guide...
  • Page 3: Table Of Contents

    GS-SR222 System Installation Guide Contents SAFE, CARE AND REGULATORY INFORMATION PREFACE INTRODUCTION 3.1. F EATURES CONTENTS PACKAGE SYSTEM INSTALLATION PROCEDURES 5.1. C HASSIS EMOVAL 5.2. CPU I NSTALLATION 5.3. H NSTALLATION 5.4. M EMORY NSTALLATION 5.5. PCI E XPANSION NSTALLATION 5.6.
  • Page 4 GS-SR222 System Installation Guide The author assumes no responsibility for any errors or omissions that may appear in this document nor does the author make a commitment to update the information contained herein. Third-party brands and names are the property of their respective owners.
  • Page 5: Safe, Care And Regulatory Information

    GS-SR222 System Installation Guide 1. Safe, Care and Regulatory Information Important safety information Read and follow all instructions marked on the product and in the documentation before you operate your system. Retain all safety and operating instructions for future use. The product should be operated only from the type of power source indicated on the rating label.
  • Page 6 GS-SR222 System Installation Guide Precautions for Products With Laser Devices Observe the following precautions for laser devices: Do not open the CD-ROM drive, make adjustments, or perform procedures on a laser device other than those specified in the product’s documentation. Only authorized service technicians should repair laser devices.
  • Page 7 GS-SR222 System Installation Guide generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
  • Page 8 GS-SR222 System Installation Guide The FCC also requires the transmitter of a FAX transmission be properly identified (per FCC Rules Part 68, Sec. 68.381 (c) (3)). / for Canadian users only / Canadian Department of Communications Compliance Statement This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the radio interference regulations of Industry Canada.
  • Page 9 GS-SR222 System Installation Guide metallic water pipe system, if resent are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading.
  • Page 10: Preface

    For your protection, please read and understand al of the safety and operating instructions regarding your Gigabyte Server and retain for future reference. The procedures in this guidebook assume that you are a system or network administrator experienced in installing similar hardware.
  • Page 11: Introduction

    GS-SR222 System Installation Guide 3. Introduction Welcome to the Gigabyte GS-SR222 Rack mount Server System Installation Guide. The guidebook provides instructions for configuration hardware for the GS-SR222 to your system. In order to get the optimal usage of your server, please pay...
  • Page 12 GS-SR222 System Installation Guide Features Description Motherboard GA-8IPXDR Processor Supported Support Dual Intel P4 Xeon Processors (Prestonia) at FSB 400Mhz and 533 Mhz Design Compliance BIOS PC2001/Win9x/ME/2000/XP, ACPI compliance Chipset Intel E7500 (Plumas) Chipset (MCH+ICH3) Intel P64H2 Memory Supported Dual Memory Channel Support 12GB Register DDR memory on 6 DDR sockets Integrated SCSI Controller...
  • Page 13 GS-SR222 System Installation Guide System Form Factor 2U, Rack-optimized design I/O expansion slots 2 full-length 64-bit/100 MHz PCI slots 1 low-profile 32bit/33 MHz PCI slots Power supply 460W maximum continuous required power Operating temperature 41 to 95 degrees F (5 to 35 degrees C)
  • Page 14: Contents Package

    GS-SR222 System Installation Guide 4. Contents Package When opening the package, please ensure the system components are not damaged during the shipping. Using the following checklist to verify the contents. If any component is missing or damaged in the system, please contact your vendor immediately.
  • Page 15: System Installation Procedures

    GS-SR222 System Installation Guide 5. System Installation Procedures Please remove the protective thin films (Top and bottom) from the system when installing. 5.1. Chassis Removal Step 1. Unscrew the two thumbscrews from the back of the system. (Fig-1) Figure 1 Figure 2 Step 2.
  • Page 16: Cpu Installation

    GS-SR222 System Installation Guide Step 3. After removing the top cover, you will see a plastic airflow duct over the CPU and Memory. Rise up the airflow duct as the clip circle shown in the picture. (Fig-3) Step 4. Install CPU and other essential components. Figure 3 5.2.
  • Page 17 GS-SR222 System Installation Guide Step 3. The noticed corner should point toward the end of lever. The CPU will only fit in the orientation as shown. (Fig-5) Figure 5 Step 4. Then, align the CPU insert it into the socket. (Fig-6) Push the lever back to the original position.
  • Page 18: Heat Sink Installation

    GS-SR222 System Installation Guide 5.3. Heat Sink Installation Step 1. Put the Heat sink on the CPU. Figure 8 Figure 9 Step 2. There are for screws hold the retention modules. Seat the heat sink firmly in the retention modules with the two cooler brackets.
  • Page 19: Memory Installation

    GS-SR222 System Installation Guide 5.4. Memory Installation The motherboard contains six DIMM (Dual Inline Memory Module) sockets. The systems BIOS will auto detect the size if the memory after installing. To install memory, simply push the memory modules into the DIMM sockets. (Fig -11 to12) Figure 11 Figure 12 5.5.
  • Page 20 GS-SR222 System Installation Guide Figure 13 Figure 14 Step 2. Then, unscrew the raiser card firming screw as the stable clip circle pointed. (Fig-16) Figure 15 Figure 16...
  • Page 21 GS-SR222 System Installation Guide Step 3. Carefully pull up and remove the PCI riser bracket. (Fig- 17). Figure 17 Step 4. Install the card into place. There are two standoff copper pillars to hold the raiser card. Secure the card with screw. Make sure it is seated properly into PCI slot.
  • Page 22: Air Flow Duct Installation

    GS-SR222 System Installation Guide Figure 20 Figure 21 Step 7. Put the PCI raiser bracket into the server system. (Fig-20) Step 8. Securing the bracket with tighten the raiser card firming screw. (Fig-21) 5.6. Air Flow Duct Installation GS-SR222 is enhanced a new device which called Airflow Duct. The main function of the airflow duct is to increase the capability of driving out the excessive system heat (Especially the CPU heat).
  • Page 23 GS-SR222 System Installation Guide Figure 22 Figure 23 Step 2. Place the airflow duct; ensuring the two stable racks are inserted correctly into the system module. (Fig-23) After inserting the airflow duct, please pay attention to the table clip circle shown in Figure 24.
  • Page 24: Reinstall Top Cover

    GS-SR222 System Installation Guide Figure 25 Figure 25 indicates the airflow duct should be flat and completely placed into the system. When the upper case is placed, please be aware that the power supply header and the motherboard should be completely placed under the duct cover. Otherwise the upper case might not be able to close tightly.
  • Page 25: Scsi Id Setting

    GS-SR222 System Installation Guide 5.8. SCSI ID Setting The SCSI ID is shown in Figure 27. If there occurs an abnormal SCSI hard disk drive behavior (e.g. does not detect the hard disk drive properly), please make sure that the each HDD has different Figure 27...
  • Page 26 GS-SR222 System Installation Guide Jumper Setting For HD1, HD2, and HD3 Jumper ON (Jumper Close): 1-2 OFF (Jumper Open): 2-3...
  • Page 27: Dock Handle Installation

    GS-SR222 System Installation Guide 5.9. Dock Handle Installation Remove the dock handles from the package. Put two on each side of the chassis, secure with screws provided. (Fig-28) Figure 28 5.10. Hard Disk Drive Installation Step 1. Pull the hard disk drive tray handle and remove the tray from the chassis (Fig-29).
  • Page 28 GS-SR222 System Installation Guide Step 2. After securing the hard disk drive with the screws, hold the hard drive handle at open position, place the tray into chassis (Fig-31) and push the hard disk drive tray handle to the closed position.
  • Page 29: Appearance Of Gs-Sr222

    GS-SR222 System Installation Guide 5.11. Appearance of GS-SR222 5.11.1. Front View of GS-SR222 6 SCSI Hot-Swap HDD CD ROM Drive Floppy Drive USB & 5.11.2. Rear View of GS-SR222 Connectors Expansion Slots Power...
  • Page 30: Led Indicator Description

    GS-SR222 System Installation Guide 5.11.3. LED Indicator Description LAN 1 LED Power LED LAN 2 LED FAN Status LED Connectors System Status LED Acting Color Status Power Green System power on System power off Green LAN online LAN LED LAN offline Blink Green LAN acting...
  • Page 31 GS-SR222 System Installation Guide HDD LED: HDD LED 1 HDD LED 2 Acting Color Status Condition No HDD Installed Non-RAID LED 1 Non-RAID Green HDD Installed LED 1 HDD idle Non-RAID LED 2 Blink Green HDD acting Non-RAID LED 2 No HDD installed/ RAID LED 1...
  • Page 32: Dual Lan Card Installation (Optional)

    GS-SR222 System Installation Guide 5.12. Dual LAN Card Installation (Optional) GS-SR222 provides optional 64bit/66 MHz dual LAN card. To install dual LAN card please follow these few steps. Step 1. There are three screws holding the riser bracket. First, remove the screw on the top of the bracket (Fig-33) then remove the two screws located at the rear.
  • Page 33 GS-SR222 System Installation Guide Step 4. Install the dual LAN card into place. (Fig-37) Figure 37 Figure 38 Step 5. Push down the bracket firmly. The card is seated properly into PCI slot. (Fig-38) Figure 39 Figure 40 Step 6. Put the PCI raiser bracket into the server system. Securing the bracket with tighten the raiser card firming screw.
  • Page 34: Connector Icon Description

    GS-SR222 System Installation Guide 5.13. Connector Icon Description Suggested icons Description Keyboard Mouse Parallel Port Serial Port...

Table of Contents