Gigabyte GS-SR295 Installation Manual

Rack mount server

Advertisement

Quick Links

GS-SR295
Rack Mount Server
System Installation Guide
Dual Xeon
(Nocona)Processor Motherboard
TM
Rev. 1.1
25A08-02950-F00

Advertisement

Table of Contents
loading

Summary of Contents for Gigabyte GS-SR295

  • Page 1 GS-SR295 Rack Mount Server System Installation Guide Dual Xeon (Nocona)Processor Motherboard Rev. 1.1 25A08-02950-F00...
  • Page 2: Table Of Contents

    Step 2-7: FAN Duct Removal and Installation .............. 18 Step 2-8: Hard Disk Drive Installation ................20 Step 2-9: Reinstall Chassis Cover ................21 Chapter 3Appearance of GS-SR295 ........... 22 3-1:Front View of GS-SR295 ..................22 3-2:Rear View of GS-SR295 ..................23 3-3: SCSI Backplane Layout and Description .............
  • Page 3: Safety, Care And Regulatory Information

    Safety Information Safety, Care and Regulatory Information Important safety information Read and follow all instructions marked on the product and in the documentation before you operate your system. Retain all safety and operating instructions for future use. * The product should be operated only from the type of power source indicated on the rating label. * If your computer has a voltage selector switch, make sure that the switch is in the proper position for your area.
  • Page 4 GS-SR295 Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle. * Disconnect the modem cable before opening a product enclosure, touching or installing internal components, or touching an uninsulated modem cable or jack.
  • Page 5 Safety Information Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect proper operation of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service. The FCC prohibits this equipment to be connected to party lines or coin-telephone service.
  • Page 6: Warning

    GS-SR295 Rack mount Server NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the sum of the Load Numbers of all the devices does not exceed 100.
  • Page 7: Introduction

    For your protection, please read and undertand all of the safety and operating instructions regarding your Gigabyte Server and retain for future reference. The procedures in this guidebook assume that your are a system or network administrator experienced in installing similar hardware.
  • Page 8: Chapter 1 Features Summary

    GS-SR295 Rack mount Server Chapter 1 Features Summary Motherboard GA-9ILDR Processor Supported Dual socket 604 for Intel Xeon(Nocona) processor suopprts ® 3.6 GB and upper Intel Xeon (Nocona) CPUs supports 800 MHz FSB ® 2nd cache depend on CPU Chipset...
  • Page 9 Feature Summary Integrated Graphics: Controller RAGE-XL VGA Controller ® Graphics Memory 8MB SDRAM Integrated Super I/O: Serial Ports 1 x Serial Port COM1 (Rear I/O-Shield) Keyboard/Mouse 1 x PS/2 Keyboard Port (Rear I/O-Shield) 1 x PS/2 Mouse Port (Rear I/O-Shield) USB 2.0 2 x USB ports (Rear I/O-Shield) 2 x USB Port (Front Panel)
  • Page 10: Chapter 2 System Overview

    GS-SR295 Rack mount Server Chapter 2 System Overview Chassis front cover Riser card bracket Chassis rear cover System Fans x 3 Single/Redundant Power supply SCSI HDD Trays x 8 GA-9ILDR Motherboard Front LEDs & Power Button Dual Sockets 604 CD-ROM & Floppy Drives...
  • Page 11: Chapter 3 System Hardware Installation

    Hardware Installation Process Chapter 3 System Hardware Installation Please observe the safety information in chapter “Important Safety Information” Do not expose the server to extreme environmental conditions. Protect it from dust, humidity, and heat. Step 2-1: Chassis Removal Front Cover: Step 1 Push down the two buttons located at two sides of the chassis.
  • Page 12: Step 2-2: Cpu Installation

    GS-SR295 Rack mount Server Step 2-2: CPU Installation Please make sure the CPU type and speed that are supported by the motherboard. Step 1. Rise the lever bar on the socket. Step 2. Aligning the pins of the processor with the socket, insert the processor into the socket.
  • Page 13: Step 2-4: Memory Installation

    Hardware Installation Process Step 2-3: CPU Heat Sink Installation Step 1 Make sure the heat sink matches exactly the four holes on the motherboard. Step 2 Attach the heat sink to the processor scoket. Lock the heat sink to the motherboard with four screws.
  • Page 14: Step 2-5: Pci Expansion Card Installation

    GS-SR295 Rack mount Server Step 2-5: PCI Expansion Card Installation GS-SR295 provides expansion riser slots for four peripheral cards, two full-heigh 64bit/100MHz PCI-X slots and one low profile with 64bit/100MHz and one low profile 64bit/133MHz PCI slots. To install the peripheral, please go through the following steps.
  • Page 15 Hardware Installation Process Step 4...
  • Page 16: Step 2-6: Pci-X Zcr Expansion Card Installation (Optional)

    GS-SR295 Rack mount Server Step 2-6: PCI-X ZCR Expansion Card Installation (Optional) Step 1 Remove two screws on the riser bracket. Step 2 Detach the riser bracket with both hands. Step 3 Align Point A to the hole located at upper right habd side (Position II) of the ZCR card. Then, secure the screw holder with screws.
  • Page 17 Hardware Installation Process Step 3 & 4 Position I Position II Step 5 Step 6 Step 7...
  • Page 18: Step 2-7: Fan Duct Removal And Installation

    GS-SR295 Rack mount Server Step 2-7: FAN Duct Removal and Installation Step 1 Remove two screws on the riser bracket. Step 2 Detach the riser bracket with both hands. Step 3 To remove the FAN duct, just pull up the screw-holder and unscrew thumbscrews to remove the FAN duct.
  • Page 19 Hardware Installation Process Step 5 Step 6 Step 7 Step 6 Step 8 Step 9...
  • Page 20: Step 2-8: Hard Disk Drive Installation

    GS-SR295 Rack mount Server Step 2-8: Hard Disk Drive Installation Step 1 Push the hard disk drive trail button. Step 2 Pull out the trail and remove the trail from the chassis. Step 3 Insert the hard disk into the trail.
  • Page 21: Step 2-9: Reinstall Chassis Cover

    Hardware Installation Process Step 2-9: Reinstall Chassis Cover Front Cover: Step 1 Insert the front edge from 15 degree. Step 2 Close the cover in un-lock position. Step 3 Slide it toward to screw lock position. Rear Cover: Step 1 Close the cover in un-lock position. Step 2 Slide it to lock position.
  • Page 22: Chapter 3Appearance Of Gs-Sr295

    GS-SR295 Rack mount Server Chapter 3 Appearance of GS-SR295 3-1: Front View of GS-SR295...
  • Page 23: 3-2:Rear View Of Gs-Sr295

    System Appearance 3-2: Rear View of GS-SR295 & e l i t o l l l u - l l t o l...
  • Page 24: 3-3: Scsi Backplane Layout And Description

    GS-SR295 Rack mount Server 3-3: SCSI Backplane Layout and Description...
  • Page 25: 3-4: Switch And Led Indicators Description

    LED Description 3-4: Switch and LED Indicators Description HDD LED LAN1 & LAN2 access LED System Health LED Power LED USB Connectors Localization LED NMI LED Reset LED Acting Color Status Power LED Green Power On Amber Power cable is plugged in No power SYS Health LED Amber...
  • Page 26: 3-5: Hdd Led Indicators Description

    GS-SR295 Rack mount Server 3-5: HDD LED Indicators Description HDD LED 1 HDD LED 2...
  • Page 27: 3-6 : Connector Icon Description

    Motherbaord Layout 3-6 : Connector Icon Description i r c i t p l a i...
  • Page 28: Chapter 4 Motherboard Layout & Jumper Setting

    GS-SR295 Rack mount Server Chapter 4 Motherboard Layout & Jumper Setting 4-1: GA-9ILDR Motherboard Layout COU P_IN3-SCSI CO M1 SCSI_ HSINK CLR_C MOS1...
  • Page 29 Motherbaord Layout CPU0 (Install First) CPU_FAN0 (CPU FAN) CPU1 CPU_FAN1 (CPU FAN) Intel E7520 SYS_FAN1 (System FAN) Intel 6700 PXH SYS_FAN2 (System FAN) LSI 1030 (SCSI Controller) PCI-6 (Supports 32bit/33MHz) ICH5R PCI-5 (Supports 64bit/66~100MHz) ATI Rage_XL PCI-4 (Supports 64bit/66~100MHz) ITE IT8712F PCIE-3 (Supports PCI Express) IDE2 PCIE-2 (Supports PCI Express)
  • Page 30: 4-2: Jumper Setting Introduction

    GS-SR295 Rack mount Server 4-2: Jumper Setting Introduction COU P_IN3-SCSI CO M1 SCSI_ HSINK CLR_C MOS1 1 ) PLL0/1 3) CLR_CMOS 2 ) CASEOPEN 4 ) CMOS_Lock...
  • Page 31 Jumper Setting 1) PLL0/1 (DDR-266/333 Speed Adjustment Jumper) COU P_I N3-SCSI COM1 Open: Set memory speed at DDR-266 Close: Set memory speed at DDR-333 SCSI_HSINK CLR_CMOS1 2) CASEOPEN (Case Open Function) COU P_IN3-SCSI COM1 Open: Disable this function Close: Enable Case open function (Default) SCSI_HSINK CLR_CMOS1...
  • Page 32 GS-SR295 Rack mount Server 3) CLR_CMOS (Clear CMOS Function) You may clear the CMOS data to its default values by this jumper. Default value doesn’t include the “Shunter” to prevent from improper use this jumper. To clear CMOS, temporarily short 1-2 pin.
  • Page 33: Chapter 5 Appendix

    Appexdix Chapter 5 Appendix 5-1: Acronyms Acronyms Meaning ACPI Advanced Configuration and Power Interface Advanced Power Management Accelerated Graphics Port Audio Modem Riser Advanced Communications Riser BIOS Boot Specification BIOS Basic Input / Output System Central Processing Unit CMOS Complementary Metal Oxide Semiconductor CRIMM Continuity RIMM Communication and Networking Riser...
  • Page 34 GS-SR295 Rack mount Server Acronyms Meaning Input / Output IOAPIC Input Output Advanced Programmable Input Controller Industry Standard Architecture Local Area Network Logical Block Addressing Light Emitting Diode Megahertz MIDI Musical Instrument Digital Interface Memory Translator Hub Memory Protocol Translator...