Summary of Contents for Gigabyte GS-SR102

  • Page 1 System Installation Guide GS-SR102/SR202 System Installation Guide...
  • Page 2: Table Of Contents

    System Installation Guide Table of Contents 1. INTRODUCTION 1.1. P REFACE 1.2. F EATURES 2. PACKAGE CONTENTS 3. SYSTEM INSTALLATION PROCEDURES 3.1. C HASSIS OVER EMOVAL 3.2. CPU I NSTALLATION 3.3. H NSTALLATION 3.4. M EMORY NSTALLATION 3.5. PCI E XPANSION NSTALLATION 3.6.
  • Page 3: Introduction

    System Installation Guide 1. Introduction 1.1. Preface This manual will assist you in installing all of the essential components for rack mount system. We recommend you keep this manual for future reference. In order to maintain the rack mount server in its original condition, please pay attention to the following tips.
  • Page 4 System Installation Guide Chipset VIA Apollo Pro Family AGPset ( VT82C694X ,VT82C686A ) Chipset ATI Rage XL VGA Chip PROMISE PDC20265R Intel 82559 Dual LAN chip Memory Support 4 168-pin 25 degree slant DIMM sockets Supports PC-100/PC-133 SDRAM and VCM SDRAM Supports up to 4.0GB SDRAM Supports only 3.3V SDRAM DIMM Storage Controller...
  • Page 5: Package Contents

    System Installation Guide 2. Package Contents When opening the package, please insure the system has not been damaged during shipping. Using the following list as a check off, verify the contents. If there is missing component or damage to the system, please inform your vendor immediately. Contents:...
  • Page 7: System Installation Procedures

    System Installation Guide 3. System Installation Procedures Warning: Please remove the protective thin films (Top and Bottom) from the system when installing. 3.1. Chassis Cover Removal Unscrew the two thumb screws from the back of the system (Fig-1). Standing at the front of the system. Gently apply force to the indentures with your thumbs and push toward the rear of the chassis for about 3/4 of an inch.
  • Page 8: Cpu Installation

    System Installation Guide Fig-3 3.2. CPU Installation To install Socket 370 CPU, lift up bar located next to the Socket. Then, insert Socket370 CPU inside Socket, and push the lever bar back into original position. (Fig-4 & Fig-5 ) CPU-2 CPU-1 Fig-4...
  • Page 9: Heat Sink Installation

    System Installation Guide Fig-5 3.3. Heat Sink Installation Click Fan+Heatsink to CPU socket 370 and plug the Fan power cable to the each single CPU cooling Fan connector on the motherboard. (Fig-6 and Fig-7) Fig-6...
  • Page 10 System Installation Guide Fig-7 For CPU1, Fan power cable connect to J13 (CPU1 FAN) connector and for CPU2, Fan power cable connect to J15 (CPU2 Fan) Connector. Note to make sure the connector is plugged into the header in the correct and firmly seated. (Fig-8) J13-CPU1 Fan Connector J15-CPU2 Fan Connector Fig-8...
  • Page 11: Memory Installation

    System Installation Guide 3.4. Memory Installation The motherboard contains four slanted DIMM (Dual Inline Memory Module) sockets. The system BIOS will auto detect the size of the memory. To install memory, simply push the memory modules into the DIMM sockets. (Fig-9) Fig-9 3.5.
  • Page 12 System Installation Guide Fig-11 Fig-10 Fig-12 Fig-13 Carefully remove the PCI raiser bracket. (Fig-12). Install the card into place. Secure the card with screw (Fig-13), make sure it is seated properly into PCI slot. Replace the raiser bracket into the PCI slot on the motherboard (Fig-14).
  • Page 13: Air Flow Ducti

    Fig-15 3.6. Air Flow Duct Installation Guide GS-SR102 and GS-SR202 have installed a new device called Air Flow Duct. The main function of Air flow duct is its capability of driving out excessive system heat(Especially the CPU Heat). In order to maintain the smooth system operation, please note that after CPU and RAM have being installed.
  • Page 14 System Installation Guide (Fig-15) Fig-16 Fig-17 Fig-18 (2.) SR-202: a. Facing the back-side of system, insert the Air Flow Duct diagonally(Fig-19) 。 b. On the other side of Air Flow Duct, follow the above instruction again.(Fig-20) 。 Finally, completely insert the Power Cable and header inside the Air Flow Duct to ensure the heat flow out smoothly.
  • Page 15: Reinstall Top Cover

    System Installation Guide Fig-19 Fig-20 Fig-21 3.7. Reinstall Top Cover When you are finish installing all the essential components from section 3.1 to 3.5, replace the transparent plastic air duct. This will ensure the air flow inside the chassis. Failure to do so may cause CPU and Memory to over heat.
  • Page 16: Scsi Id Settings

    System Installation Guide Fig-22 3.8. SCSI ID Settings The SCSI ID is preset as shown in Fig-23 during manufacture. If there is a abnormal SCSI hard disk drive behavior e.g. does not find hard disk drive properly, please make sure HD1, HD2 and HD3 have different IDs.
  • Page 17: Jumper Setting For 3.10. Dock Handlesi

    System Installation Guide 3.9. Jumper setting for HD1 ‘ HD2 and HD3 Jumper ON( Jumper Close ):1-2 OFF( Jumper Open ):2-3 3-11...
  • Page 18: Hard Disk Drivei

    System Installation Guide 3.10. Dock Handles Installation Remove dock handles from the package. Put two on each side of the chassis, secure with screws provided (Fig-24). Fig-24 3.11. Hard Disk Drive Installation Pull the hard disk drive tray handle and remove the tray from the chassis (Fig-25).
  • Page 19 System Installation Guide After hard disk drive is secure with the screws hold the hard drive handle at open position and insert the tray into chassis (Fig-27). When the hard disk drive connector meets the SCSI back plane, push the hard disk drive tray handle to the closed position.(Fig-28)...
  • Page 20: Front Panel

    System Installation Guide 3.12. Front Panel USB & LED SR-102 CD-ROM Drive Serial Port Floppy Drive SR-202 Serial Port USB & LED CD-ROM Drive Floppy Drive 3.13. LED Panel LAN Activity Power LED Fan Status Connector System Status Power LED: Green-Online Off-Offline LAN Activity: Green-Online Off-Offline...
  • Page 21: Rear Panel

    System Installation Guide Fan Status: Orange-Operational Off-Malfunction HDD Power LED: HDD LED1 HDD LED2 HDD LED1-Off-No hard drive installed HDD LED1-Green-HDD installed HDD LED2-Flashing-HDD activity 3.14. Rear Panel Expansion Ultra dense Power Connectors slots SCSI 3.15. Dual LAN Card Installation ( Optional ) GS-SR202 provides optional 32bit/33MHz dual LAN card .
  • Page 22 System Installation Guide bracket .First ,remove the screw on the top of the bracket ( Fig-29 ) then remove the two screws located at the rear . ( Fig-30 ) b. Care fully remove the PCI raiser bracket . ( Fig-31 ) c.
  • Page 23 System Installation Guide Fig-33 Fig-34 d. After that before the raiser bracket into the PCI slot motherboard , remove the mother board from chassis and change IO shielding plate first .And then put raiser bracket into the PCI slot on motherboard .( Fig-35 & Fig-36 ) Fig-35 Fig-36 3-17...
  • Page 24: Connector Icons

    System Installation Guide 3.16. Connector Icons Suggested icons Description Keyboard Mouse Parallel Port Serial Port 3-18...