Gigabyte GS-SR195H System Installation Manual
Gigabyte GS-SR195H System Installation Manual

Gigabyte GS-SR195H System Installation Manual

1u rack mount server

Advertisement

Quick Links

GS-SR195H
1U Rack Mount Server
System Installation Guide
Intel
Pentium Xeon Processor Serverboard
®
Rev. 1.0
25A080-095H0-F00

Advertisement

Table of Contents
loading

Summary of Contents for Gigabyte GS-SR195H

  • Page 1 GS-SR195H 1U Rack Mount Server System Installation Guide Intel Pentium Xeon Processor Serverboard ® Rev. 1.0 25A080-095H0-F00...
  • Page 2: Table Of Contents

    Step 2-5: PCI Expansion Card Installation ..............15 Step 2-6: Hard Disk Drive Installation ................16 Step 2-7: ZCR Installation and Removal (Optional Device) ........17 Chapter 3 Appearance of GS-SR195H ..........18 3-1: Front View of GS-SR195H ..................18 3-2: Rear View of GS-SR195H ..................19 3-3: Switch and LED Indicators Introduction ..............
  • Page 3 Table of Content Chapter 5 BIOS Setup ................28 Main ......................30 Advanced ....................33 PCI Configuration ......................34 Advanced Chipset Control ..................... 36 Advanced Processor Options ..................38 Peripheral Configuration ....................40 Security ...................... 45 Console Redirection ......................47 Server ......................
  • Page 4: Safety, Care And Regulatory Information

    GS-SR195H Rack Mount Server Safety, Care and Regulatory Information Important safety information Read and follow all instructions marked on the product and in the documentation before you operate your system. Retain all safety and operating instructions for future use. * The product should be operated only from the type of power source indicated on the rating label.
  • Page 5 Safety Information * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle. * Disconnect the modem cable before opening a product enclosure, touching or installing internal components, or touching an uninsulated modem cable or jack.
  • Page 6 GS-SR195H Rack Mount Server Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect proper operation of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service.
  • Page 7 Safety Information NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the sum of the Load Numbers of all the devices does not exceed 100.
  • Page 8: Introduction

    For your protection, please read and undertand all of the safety and operating instructions regarding your Gigabyte Server and retain for future reference. The procedures in this guidebook assusme that your are a system or network administrator experienced in installing similar hardware.
  • Page 9: Chapter 1 Features Summary

    Feature Summary Chapter 1 Features Summary Motherboard GA-9IVDPH Processor Supported Dual socket 604 for Intel Xeon(Nocona/Irwindale) processor ® suopprts 3.6 GB and upper Intel Xeon (Nocona/Irwindale) CPUs supports 800 MHz FSB ® 2nd cache depend on CPU Chipset Intel E7320 Chipset ®...
  • Page 10 GS-SR195H Rack Mount Server Front Panel Power SW, Reset SW, UID SW, NMI SW, 2 x LAN LED 1 x Power/Sleep LED 1 x HDD Access LED 1 x ID LED 1 x NMI LED 3 x HDD LED (on the HDD box)
  • Page 11 Feature Summary Environment Ambient Temperature Operating Temperature: 5 C to 35 Non-operating Temperature: 0 C to 50 Relative Humidity 10-80% operating Humidity at 30 Safety Regulations FCC, CE, BSMI, CB, System Dimention: 19"W x 1.73"H x 28.1"D Electrical Power Supply Redundant Power Supply 525W (1+1) Note: 1.
  • Page 12: Chapter 2 System Hardware Installation

    GS-SR195H Rack Mount Server Chapter 2 System Hardware Installation Please observe the safety information in chapter “Important Safety Information” Do not expose the server to extreme environmental conditions. Protect it from dust, humidity, and heat. Step 2-1: Chassis Removal and Installation Step 1 Loosen the thumbscrew from the back of the server.
  • Page 13: Step 2-2: Cpu Installation

    Hardware Installation Process Step 2-2: CPU Installation Please make sure the CPU type and speed that are supported by the motherboard. Step 1 Raise the locking bar on the socket. Step 2 Aligning the pins of the processor with the socket, insert the processor into the socket. Step 3 Close the handle completely and finish CPU installation.
  • Page 14: Step 2-3: Heat Sink Installation

    GS-SR195H Rack Mount Server Step 2-3: Heat Sink Installation Step 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well remember to apply the thermal conductivity compound on the CPU. Step 2 Seat the heat sink with the four screws. Installation completed.
  • Page 15: Step 2-5: Pci Expansion Card Installation

    Hardware Installation Process Step 2-5: PCI Expansion Card Installation GS-SR195H provides expansion riser slot for one PCI-X 64/66MHz slot; and one with PCI-E x8 slots. To install the peripheral, please go through the following steps. Note: Before installing the PCI expansion card, please check the card size limitation. Size limitation for PCI-E is listed below: Heigth: 18.73mm(max) ;...
  • Page 16: Step 2-6: Hard Disk Drive Installation

    GS-SR195H Rack Mount Server Step 2-6: Hard Disk Drive Installation Step 1 Press the release button and pull the blank out of the drive bay. Step 2 Slide hard disk into blank and secure it with screws Step 3 To replace the hard drive blank, slide the blank into the bay until it locks into place. Connect cable and power..
  • Page 17: Step 2-7: Zcr Installation And Removal (Optional Device)

    Hardware Installation Process Step 2-7: ZCR Installation and Removal (Optional Device) Step 1 Aling a ZCR on the module such that the notch on the ZCR exactly match the notches in the module. Step 2 Push the card in untill it clicks. Then, press down the card vertically. Step 3 To remove the ZCR card, unlock the ZCR retaining clips.
  • Page 18: Chapter 3 Appearance Of Gs-Sr195H

    GS-SR195H Rack Mount Server Chapter 3 Appearance of GS-SR195H 3-1: Front View of GS-SR195H c t i &...
  • Page 19: 3-2: Rear View Of Gs-Sr195H

    System Appearance 3-2: Rear View of GS-SR195H s t r r o t r o t t r o t r o t r o r o t e l i f t o l - l l t o l...
  • Page 20: 3-3: Switch And Led Indicators Introduction

    GS-SR195H Rack Mount Server 3-3: Switch and LED Indicators Introduction B B U U Z Z Z Z E E R R B B U U Z Z Z Z E E R R R R E E S S E E T T...
  • Page 21: 3-4: Lan Led Description

    LED Description 3-4: LAN LED Description Name Color Condition Description Green LAN Link / no Access Link/Activity Green BLINK LAN Access Idle GbE LAN Yellow 1Gbps connection Speed Green 100Mbps connection 10Mbps connection...
  • Page 22: 3-5 : Connector Icon Description

    GS-SR195H Rack Mount Server 3-5 : Connector Icon Description i r c i t p l a i...
  • Page 23: Chapter 4 Motherboard Layout & Jumper Setting

    Motherboard Layout Chapter 4 Motherboard Layout & Jumper Setting 4-1: GA-9IVDPH Motherboard Layout...
  • Page 24 GS-SR195H Rack Mount Server CPU 0 DDR A2 CPU1 DDR B2 Intel MCH E7320 DDR A3 ® R7000M DDR B3 ® Intel 6300ESB DDR A4 ® Intel 82541 DDR B4 ® Battery IPMB1 IT8712F-IX Adaptec AIC-7902W SCSI2 PCI-X_1 (64/66MHz) PCI-E x8...
  • Page 25: 4-2: Ddr Dimm Slot Population

    Motherboard Layout 4-2: DDR DIMM Slot Population Table 4-2-1: Supported DDR266 DIMM Populations NOTE!! For DDR-266 DIMM population, DIMM must be populated starting from the A4/B4 slots. Table 4-2-2: Supported DDR333 DIMM Populations NOTE!! For DDR-333 DIMM population, DIMM must be populated starting from the A3/B3 slots.
  • Page 26: 4-3: Jumper Setting

    GS-SR195H Rack Mount Server 4-3: Jumper Setting CLR_CMOS ( (Clear CMOS Function) You may clear the CMOS data to its default values by this jumper. Default value doesn’t include the “Shunter” to prevent from improper use this jumper. To clear CMOS, temporarily short 1-2 pin.
  • Page 27 Jumper Setting JP9 (Case Open Function) Open: Disable this function Close: Enable Case open function (Default)
  • Page 28: Chapter 5 Bios Setup

    GS-SR195H Rack Mount Server Chapter 5 BIOS Setup BIOS Setup is an overview of the BIOS Setup Program. The program that allows users to modify the basic system configuration. This type of information is stored in battery-backed CMOS RAM so that it retains the Setup information when the power is turned off.
  • Page 29: Getting Help

    BIOS Setup GETTING HELP Main Menu The on-line description of the highlighted setup function is displayed at the bottom of the screen. Status Page Setup Menu / Option Page Setup Menu Press F1 to pop up a small help window that describes the appropriate keys to use and the possible selections for the highlighted item.
  • Page 30: Main

    GS-SR195H Rack Mount Server Main Once you enter Phoenix BIOS Setup Utility, the Main Menu (Figure 1) will appear on the screen. Use arrow keys to select among the items and press <Enter> to accept or enter the sub-menu. PhoenixBIOS Setup Utility...
  • Page 31: Legacy Diskette A

    BIOS Setup Legacy Diskette A This category identifies the type of floppy disk drive A that has been installed in the computer. Disabled Disable this device. 360KB, 5 inch AT-type high-density drive; 360K byte capacity 1.2MB, 3 inch AT-type high-density drive; 1.2M byte capacity 720K, 3 inch double-sided drive;...
  • Page 32: System Information

    GS-SR195H Rack Mount Server Multi-Sector Transfer This field displays the information of Multi-Sector Transfer Mode. Disabled: The data transfer from and to the device occurs one sector at a time. Auto: The data transfer from and to the device occurs multiple sectors at a time if the device supports it.
  • Page 33: Advanced

    BIOS Setup Advanced About This Section: Advanced With this section, allowing user to configure your system for basic operation. User can change the processor options, chipset configuration, PCI configuration and chipset control. PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit PCI Configuration Item Specific Help...
  • Page 34: Pci Configuration

    GS-SR195H Rack Mount Server PCI Configuration PhoenixBIOS Setup Utility PCI Configuration Item Specific Help Embedded Vedio Controller Embedded SCSI Controller Embedded NIC F1: Help : Select Item + -: Change Values F9: Setup Defaults Esc: Exit : Select Menu Enter: Select Sub-Menu F10: Save&Exit...
  • Page 35 BIOS Setup Embedded NIC (Gbit #1 / 2) Onboard LAN Control Enabled Enable onboard LAN 1 / 2 device. (Default value) Disabled Disable this function. Option ROM Scan Enabled Enableing this item to initialize device expansion ROM. Disabled Disable this function. (Defualt value)
  • Page 36: Advanced Chipset Control

    GS-SR195H Rack Mount Server Advanced Chipset Control PhoenixBIOS Setup Utility Advanced Chipset Control Item Specific Help USB Controller [Enabled] Legacy USB Support [Disabled] Force Compliance Mode [Enabled] PCI-E port A Device 2 [Enabled] 4GB PCI Hole Granularity [128MB] Data Parity Error Recovery...
  • Page 37: Wake On Lan

    BIOS Setup Force Compliance Mode This option allows user to function PCI-E Compliance mode by setting item to desired value. Enabled Enables PCI-E Force Compliance mode. (Default Value) Disabled Disables this function. PCI-E port A Device 2 Force PCI Express v1.0 Compability Mode, this PCI-E port A by setting to desired value. Force PCI Express 1.0 Force PCI Express v1.0 Compability Mode.
  • Page 38: Advanced Processor Options

    BIOS Setup Advanced Processor Options PhoenixBIOS Setup Utility Advanced Processor Options Item Specific Help Hyper Threading Technology [Enabled] Machine Cecking [Disabled] Thermal Management 2 [Disabled] Adjacent Cache Line Prefetch [Enabled] Set Max Ext CPUID = 3 [Disabled] Thermal Management 1 [Disabled] NX Protection [Enabled]...
  • Page 39 GS-SR195H Rack Mount Server Thermal Managerment 2 Select between TM1 and TM2. Enabled Select Thermal Management 2 function. Disabled Disable this function. (Default value) Adjacent Cache Line Prefetch Enabled Processor will fetch both cache lines when it requires data that is not currently inits cache.
  • Page 40: Peripheral Configuration

    BIOS Setup Peripheral Configuration PhoenixBIOS Setup Utility Peripheral Configuration Item Specific Help Serial Port A [Enabled] Base I/O address/IRQ [3F8/IRQ4] Serial Port B [Enabled] Base I/O address/IRQ [2F8/IRQ3] Parallel Port [Enabled] Mode [Bi-directional] Base I/O addreee [378] Floppy disk controller [Enabled] Floppy Check [Enabled]...
  • Page 41: Serial Port B

    GS-SR195H Rack Mount Server Serial Port B This allows users to configure serial prot B by using this option. Disabled Disable the configuration. Enabled Enable the configuration (Default value) Base I/O Address/IRQ 3F8/IRQ4 Set IO address to 3F8. 2F8/IRQ3 Set IO address to 2F8.
  • Page 42 GS-SR195H Rack Mount Server Floppy disk controller Enabled Enable the floppy disk controller. (Default value) Disabled Disable the device. Floppy Check Enabled Enable the device to verify floppy typer when system boot. Disabled Disable the this function. (Default value)
  • Page 43: Reset Configuration Data

    GS-SR195H Rack Mount Server PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit PCI Configuration Item Specific Help Advanced Chipset Control Advanced Processor Options Peripheral Configuration Reset Configuration Data [No] ClkGen Spread Spectrum [Disabled] System After AC Back [Pre-State] Extended Memory Testing...
  • Page 44 BIOS Setup Extended Memory Testing Determine which type of tests will be performed extended memory. (above 1M) Enabled Enable Extended Memory Testing. (Default value) Disabled Disable this function. Network Server Enabled System will be secured at boot to prevent tampering during network operation.
  • Page 45: Security

    GS-SR195H Rack Mount Server Security PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit Supervisor Password Is: Clear Item Specific Help User Password Is: Clear Set Supervisor Password [Enter] Set User Password [Enter] Password On Boot [Disabled] F1: Help : Select Item...
  • Page 46 BIOS Setup Set User Password You can only enter but do not have the right to change the options of the setup menus. When you select this function, the following message will appear at the center of the screen to assist you in creating a password.
  • Page 47: Console Redirection

    GS-SR195H Rack Mount Server Server PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit Console Redirection Item Specific Help Halt On [Mid] Memory RAS Feature Control [Standard] Clear all Event Logs: Enter Log POST Sys Event [Disbled] BMC action for IERR:...
  • Page 48: Flow Control

    BIOS Setup Com Port Address If this option is set to enabled, it will use a port on the motherboard. On-board COMA Use COMA as he COM port address. On-board COMB Use COMB as he COM port address. Disabled Disable this function. (Default value) Baud Rate This option allows user to set the specified baud rate.
  • Page 49 GS-SR195H Rack Mount Server Halt On The category determines whether the computer will stop if an error is detected during power up. NO Errors The system boot will not stop for any error that may be detected and you will be prompted.
  • Page 50 GS-SR195H Rack Mount Server Please note that the following item will be shown when IPMI card is populated Clear all Event Log Press [Enter] to clear all system event log. When you press [Enter] on this itemm, you wiil get...
  • Page 51: Boot

    GS-SR195H Rack Mount Server Boot PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit + CD-ROM Drive Item Specific Help + Hard Drive Removable Device F1: Help : Select Item + -: Change Values F5: Setup Defaults Esc: Exit : Select Menu...
  • Page 52: Exit

    GS-SR195H Rack Mount Server Exit PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit Exit Saving Changes Item Specific Help Exit Discarding Changes Load Settup Default Discard Changes Save Changes F1: Help : Select Item + -: Change Values F5: Setup Defaults...
  • Page 53: Exit Discarding Changes

    BIOS Setup Exit Saving Changes This option allows user to exit system setup with saving the changes. Press <Enter> on this item to ask for the following confirmation message: Pressing ‘Y’ to store all the present setting values tha user made in this time into CMOS. Therefore, whenyou boot up your computer next time, the BIOS will re-configure your system according data in CMOS.
  • Page 54 GS-SR195H Rack Mount Server Discard Changes This option allows user to load previos values from CMOS for all setup item. When you press <Enter> on this item, you will get a confirmation dialog box with a message as below: Setup Confirmation...
  • Page 55: Chapter 6 Appendix

    Appexdix Chapter 6 Appendix 6-1: Acronyms Acronyms Meaning ACPI Advanced Configuration and Power Interface Advanced Power Management Accelerated Graphics Port Audio Modem Riser Advanced Communications Riser BIOS Boot Specification BIOS Basic Input / Output System Central Processing Unit CMOS Complementary Metal Oxide Semiconductor CRIMM Continuity RIMM Communication and Networking Riser...
  • Page 56 GS-SR195H Rack Mount Server Acronyms Meaning Input / Output IOAPIC Input Output Advanced Programmable Input Controller Industry Standard Architecture Local Area Network Logical Block Addressing Light Emitting Diode Megahertz MIDI Musical Instrument Digital Interface Memory Translator Hub Memory Protocol Translator...