Printing Of Photosensor Calibration Values - Olivetti XZAC4219-03 PR2 plus Service Manual

Table of Contents

Advertisement

4.3.1.1

PRINTING OF PHOTOSENSOR CALIBRATION VALUES

The calibration values of the photosensors are printed in order to obtain a reference between the previous
calibration and that carried out subsequently.
To calibrate the alignments, proceed as follows.
1.
Switch on the printer with the cover open and holding down the three buttons on the console.
2.
Wait for the acoustic signal that indicates access to the calibration and adjustment procedure,
then close the cover.
3.
Press the STATION 1 button.
4.
Press the LOCAL button.
5.
At the end of reset, introduce an A4 sheet.
6.
The form will be introduced, printed and automatically ejected. The printer moves automatically
to the next calibration.
XZAC4219-03
Service Manual
4-19