Olivetti XZAC4219-03 PR2 plus Service Manual page 71

Table of Contents

Advertisement

If calibration fails, the faulty photosensor will be indicated by the configurations of the leds. Pressing one the
console button highlights any other faulty photosensors. If calibration is not completed correctly, it will not be
possible to make the other calibrations or measurements. If calibration is successful, insert a sheet of A4
format paper in order to print the calibration values. The parameters to be checked are indicated in the table
below.
photosensor
photo n. 1 front paper present
photo n. 2 front paper present
photo n. 1 front. paper align.
photo n. 3 front paper align.
photo n. 2 front paper align.
photo n. 4 front paper align.
photo rear paper present
photo paper top edge
Parameters to be checked
1) MINIMUM ACCEPTABLE VALUE 4500
2) VALUE
<
3) B – A
2500 MINIMUM ACCEPTABLE VALUE
Make a further check inserting a check format form code 152136J at the two ends and in the center of the slot
with the shorter side parallel to the axis of the photosensors (checking correct functioning of these).
Note: The parameters indicated above are for guidance and reference purposes in order to know the
functioning range in which the PR2 plus is positioned with regard to acceptability of the documents.
4-18
1
Paper No
(mV.)
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
A
XXXX
3
1500
2
Paper Yes
(mV.)
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
B
XXXX
Average
Current
val.
(mA.)
(mV.)
XXXX
XX
XXXX
XX
XXXX
XX
XXXX
XX
XXXX
XX
XXXX
XX
0
0
XZAC4219-03

Advertisement

Table of Contents
loading

Table of Contents