Ezm Group Options (Addr 2600-2643) - NAPCO Gemini GEM-X255 Programming Instructions Manual

Hide thumbs Also See for Gemini GEM-X255:
Table of Contents

Advertisement

WI1092B 9/02
EZM Group 1
EZM Group 2
ZONES 9-12
ZONES 13-16
ADDRESS 2600
ADDRESS 2601
LEFT
RIGHT
LEFT
blank (•)
blank (•)
EZM Group 7
EZM Group 8
ZONES 33-36
ZONES 37-40
ADDRESS 2606
ADDRESS 2607
LEFT
RIGHT
LEFT
blank (•)
blank (•)
EZM Group 13
EZM Group 14
ZONES 57-60
ZONES 61-64
ADDRESS 2612
ADDRESS 2613
LEFT
RIGHT
LEFT
blank (•)
blank (•)
EZM Group 19
EZM Group 20
ZONES 81-84
ZONES 85-88
ADDRESS 2618
ADDRESS 2619
LEFT
RIGHT
LEFT
blank (•)
blank (•)
NOTE: Zones 1-8 are included in the control panel and Zones 9-96 (Groups 1-22) are EZM Zones (either Wireless or Hardwired).
EZM GROUP OPTIONS: Up to 22 Groups of 4 Zones each may be programmed depending on the number of
EZM TYPE
zones used and which EZM modules are connected. Each group represents 4 zones.
DATA
!
ENTRIES
OPTION
1. Select EZM type from the table shown.
RIGHT
!
2. Enter in corresponding address locations above (right digit only).
Not used
blank (•)
(No EZM
NOTE: Dark shaded data value box shows option not available.
present)
1
4-Zone EZM
EZM PGM TERMINAL CONTROL
AREAS 5-8
LEFT DATA VALUES
GROUP
"
)
(CIRCLE
NO.
A8
A7
A6
A5
8
4
2
1
1
8
4
2
1
2
8
4
2
1
3
8
4
2
1
4
8
4
2
1
5
8
4
2
1
6
8
4
2
1
7
8
4
2
1
8
8
4
2
1
9
8
4
2
1
10
8
4
2
1
11
EZM PGM ARMED TERMINAL CONTROL: For each zone group select the area(s) which, when armed, will activate the PGM Lug on
the corresponding EZM modules. Each zone group corresponds to 4 zones. If 8-Zone EZMs are used each one is treated as TWO
zone groups. NOTE: Lug goes ACTIVE (low) when ANY selected area is armed. When activated, the PGM Lug goes negative (to
Ground).
!
1. Select the desired group number.
!
2. Enable desired options for each area by drawing a circle " around its corresponding binary data value.
NOTE: No circle = feature disabled.
!
3. Enter data in corresponding left and right digit address locations above.
L
NAPCO Security Systems
EZM GROUP OPTION S (ADDRESS 2600-2621)
EZM Group 3
ZONES 17-20
ADDRESS 2602
RIGHT
LEFT
RIGHT
blank (•)
EZM Group 9
ZONES 41-44
ADDRESS 2608
RIGHT
LEFT
RIGHT
blank (•)
EZM Group 15
ZONES 64-68
ADDRESS 2614
RIGHT
LEFT
RIGHT
blank (•)
EZM Group 21
ZONES 89-92
ADDRESS 2620
RIGHT
LEFT
RIGHT
blank (•)
AREAS 1-4
ADDRESS
RIGHT DATA VALUES
"
2622-2632
)
(CIRCLE
A4
A3
A2
A1
L ADDR R
8
4
2
1
2622
8
4
2
1
2623
8
4
2
1
2624
8
4
2
1
2625
8
4
2
1
2626
8
4
2
1
2627
8
4
2
1
2628
8
4
2
1
2629
8
4
2
1
2630
8
4
2
1
2631
8
4
2
1
2632
[Default = blank (•) blank (•) from address 2622-2643]
EZM Group 4
EZM Group 5
ZONES 21-24
ZONES 25-28
ADDRESS 2603
ADDRESS 2604
LEFT
RIGHT
LEFT
blank (•)
blank (•)
EZM Group 10
EZM Group 11
ZONES 45-48
ZONES 49-52
ADDRESS 2609
ADDRESS 2610
LEFT
RIGHT
LEFT
blank (•)
blank (•)
EZM Group 16
EZM Group 17
ZONES 69-72
ZONES 73-76
ADDRESS 2615
ADDRESS 2616
LEFT
RIGHT
LEFT
blank (•)
blank (•)
EZM Group 22
Default depends on Easy Menu Question "# OF ZNS
ZONES 93-96
IN AREA1" and "# OF ZNS IN AREA2". For example, If 96
zones are used, then all 22 groups will be
ADDRESS 2621
automatically enabled. If only 8 zones are used,
LEFT
RIGHT
then groups 1-22 will be automatically disabled.
blank (•)
EZM PGM TERMINAL CONTROL
AREAS 5-8
LEFT DATA VALUES
GROUP
"
)
(CIRCLE
NO.
A8
A7
A6
A5
8
4
2
1
12
8
4
2
1
13
8
4
2
1
14
8
4
2
1
15
8
4
2
1
16
8
4
2
1
17
8
4
2
1
18
8
4
2
1
19
8
4
2
1
20
8
4
2
1
21
8
4
2
1
22
X
GEM-X255 Programming Instructions
!
Page 45
EZM Group 6
ZONES 29-32
ADDRESS 2605
RIGHT
LEFT
RIGHT
blank (•)
EZM Group 12
ZONES 53-56
ADDRESS 2611
RIGHT
LEFT
RIGHT
blank (•)
EZM Group 18
ZONES 77-80
ADDRESS 2617
RIGHT
LEFT
RIGHT
blank (•)
AREAS 1-4
ADDRESS
RIGHT DATA VALUES
"
2633-2643
)
(CIRCLE
A4
A3
A2
A1
L ADDR R
8
4
2
1
2633
8
4
2
1
2634
8
4
2
1
2635
8
4
2
1
2636
8
4
2
1
2637
8
4
2
1
2638
8
4
2
1
2639
8
4
2
1
2640
8
4
2
1
2641
8
4
2
1
2642
8
4
2
1
2643