B.3.6. Daisy Chain between Methods A and B
In rare situations where more braids need to be terminated for a connector than three per ring terminal and
a mixture of Methods A and B have been used, it is allowable to daisy chain a maximum of two shields
together from a Method A termination to a Method B (Figure B-11). All other restrictions and
instructions for the shield termination technique set forth for Method A and B are still applicable.
The maximum length of the combined braids should be approximately 4 inches.
Figure B-11. Daisy Chain between Methods A and B
B.3.7 ID Program Pins (Strapping)
The GDU 37X rear connector (J3701) is electrically isolated. For installations using
programming pins, a ground pin must be tied to the connector shell.
ID Program Pins provide a ground reference used by the hardware as a means of configuration for system
identification. The following instructions will illustrate how this ground strapping should be
accomplished with the Jackscrew Backshell:
1. Cut a 4 inch length of 22 AWG insulated wire.
Flat Braid is not permitted for this purpose. Use only insulated wire to avoid inadvertent
ground issues that could occur from exposed conductors.
2. Strip back approximately 0.17 inches of insulation and crimp a contact (item 6) to the 4" length of
22 AWG insulated wire. It is the responsibility of the installer to determine the proper length of
insulation to be removed. Wire must be visible in the inspection hole after crimping and the
insulation must be 1/64 – 1/32 inches from the end of the contact as shown in Figure B-7.
3. Insert newly crimped pins and wires into the appropriate connector housing location as specified
by the installation wiring diagrams.
4. At the end opposite the pin on the 22 AWG insulated wire strip back 0.2 inches of insulation.
5.
Terminate this end via the ring terminals with the other Flat Braid per Steps 8 and 11 pertaining
to shield termination. If this ground strap is only wire
insulated, 18-22 AWG (MS25036-149).
G3X Installation Manual – Connector Installation Instructions
190-01115-01
NOTE
NOTE
WARNING
to terminate, attach a Ring terminal, #8,
Page B-15
Revision E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents