Trim/Flap Position Input Calibration – The Pos 1 – 5 inputs require calibration if configured for any of
the trim positions (elevator, aileron, rudder) or flap position.
To perform the Trim/Flap Position calibration:
1. Press the Calibrate softkey to display the Calibration Page.
2. Position the elevator to match the trim position (up/left, neutral, down/right) displayed on the
calibration page, or position the flap to the desired position.
3. Note the resulting sensor value (in volts) displayed in the Sensor Value field (the sensor value
should change with each change in trim/flap position.
4. Highlight and press the Calibrate button.
5. Repeat this process for each of the Trim/Flap Positions.
Flap position values (up to 8) should coincide with the angle of the flap position as
expressed in degrees (-90° – +90°).
To delete a calibration value, highlight the desired data in the list, and press the CLR Key. Then highlight
Yes on the pop-up window, and press the ENT Key, the calibration data is removed.
G3X Installation Manual – Engine Sensor Installation and Configuration
190-01115-01
NOTE
Page 8-35
Revision E