Garmin G3X Installation Manual page 208

Hide thumbs Also See for G3X:
Table of Contents

Advertisement

B.3.2 Shield Termination Technique – Method A.1 (Standard)
For the following steps please refer to the drawings showing the installation of a
Jackscrew Backshell.
1. The appropriate number of Jackscrew Backshells will be included in the particular LRU
connector kit.
Table B-6. Shielded Cable Preparations for Garmin Connectors
Number
Backshell
of Pins
Size
Std/HD
1
9/15
2
15/26
3
25/44
4
37/62
5
50/78
2. At one end of a shielded cable (item 2) measure a distance between "Window Min" to "Window
Max" (Table B-6) and cut a window (max size 0.35") in the jacket to expose the shield
(Figure B-6). Use caution when cutting the jacket to avoid damaging the individual braids of the
shield. When dealing with a densely populated connector with many cables, it may prove
beneficial to stagger the windows throughout the "Window Min" to "Window Max" range. If
staggering is not needed the "Ideal Window" length is recommended.
Suggested tools to accomplish the window cut:
Coaxial Cable Stripper
Thermal Stripper
Sharp Razor Blade
Page B-8
Revision E
Figure B-6. Method A.1 for Shield Termination
Float
Float
Min
Max
(inches)
(inches)
1.25
2.25
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
NOTE
Window
Ideal Float
(inches)
(inches)
1.75
2.0
2.0
2.0
2.0
G3X Installation Manual – Connector Installation Instructions
Window
Min
Max
Window
(inches)
(inches)
2.75
5.25
3.0
5.5
3.0
5.5
3.0
5.5
3.0
5.5
190-01115-01
Ideal
4.25
4.5
4.5
4.5
4.5