Table B-7. Shielded Cable Preparations – (Quick Term)
Backshell
Size
B.3.5. Shield Termination-Method B.2 (Daisy Chain-Quick Term)
In rare situations where more braids need to be terminated for a connector than three per ring terminal it is
allowable to daisy chain a maximum of two shields together before coming to the ring terminal
(Figure B-10). All other restrictions and instructions for the shield termination technique set forth for
Method B.1 are still applicable.
The
maximum
4 inches.
Figure B-10. Method B.2 (Daisy Chain-Quick Term) for Shield Termination
Page B-14
Revision E
Number of
Pins
Std/HD
1
9/15
2
15/26
3
25/44
4
37/62
5
50/78
length
of
the
combined
Quick
Quick
Term
Term
Min
Max
(inches)
(inches)
1.25
2.25
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
NOTE
braids
should
G3X Installation Manual – Connector Installation Instructions