This section describes operating controls and indicators, dispensed product conditions, operating
characteristics, Unit operation, replenishing syrup supply, product flavor change, checking CO supply, operators
daily cleaning of Unit, and sanitizing requirements.
WARNING: Disconnect electrical power to the Unit to prevent personnel injury before
attempting any internal maintenance. Only qualified personnel should service internal
components or electrical wiring.
NOTE: The No. 1 freeze cylinder (see Figure 4) is the left-hand cylinder facing the front of the Unit. No.
2 freeze cylinder is to the right of No. 1 freeze cylinder.

CONTROL PANEL SWITCHES AND DISPLAYED MESSAGES

CONTROL PANEL SWITCHES

The Unit is equipped with one control panel which is equipped with a message display (See Figure 4).
The control panel controls operation of the No. 1 and the No. 2 freeze cylinders.
''FILL 1'' and ''FILL 2'' Control Switches.
''FILL 1'' and ''FILL 2'' control switches, located on control panel (see Figure 4), are touch-type switches and
require only pressing to activate. ''FILL 1'' and ''FILL 2'' control switches are used when filling syrup systems
sold-out floats during syrup replenishing, syrup flavor changeover, or sanitizing syrup systems. After syrup
systems sold-out floats have been filled, ''FILL 1'' and ''FILL 2'' switches may be used to prevent more product
entering product blender tanks during BRIX test.
''AUTO BLEND 1'' and ''AUTO BLEND 2'' Control Switches.
''AUTO BLEND 1'' and ''AUTO BLEND 2'' control switches, located on control panel (see Figure 4), are
touch-type switches and require only pressing to activate. These switches are used to fill product blender tanks
after sold-out floats have been filled using ''FILL 1'' and ''FILL 2'' switches. ''AUTO BLEND 1'' and ''AUTO
BLEND 2'' and ''AUTO 1'' and ''AUTO 2'' switches must be pressed to operate freeze cylinders beaters and
refrigeration system during normal operation.
''WASH 1'' and ''WASH 2'' Control Switches.
''WASH 1'' and ''WASH 2'' control switches, located on control panel (see Figure 4), are touch-type switches and
require only pressing to activate. These switches are used to operate freeze cylinders beaters with no
refrigeration during sanitizing.
''AUTO 1'' and ''AUTO 2'' Control Switches.
''AUTO 1'' and ''AUTO 2'' control switches, located on control panel (see Figure 4), are touch-type switches and
require only pressing to activate. These switches are used to operate freeze cylinders beaters and refrigeration
system after cylinders have been filled with product. Freeze cylinders beaters and refrigeration system may be
stopped by pressing ''OFF 1'' or ''OFF 2'' switches.
''OFF 1'' and ''OFF 2'' Control Switches.
''OFF 1'' and ''OFF 2'' control switches, located on control panel (see Figure 4), are touch-type switches and
require only pressing to activate. These switches are used to stop freeze cylinders beaters and refrigeration
system.