Sleep'' (Sleep Time); Wake Up'' (Wake Up Time) - Cornelius FCB 3 H.P. POST-MIX DISPENSER Installation & Service Manual

Two-flavor w/hot-gas defrost and v3+ features
Table of Contents

Advertisement

''SLEEP'' (SLEEP TIME)

''SLEEP'' (SLEEP TIME) may be programmed into Unit to allow Unit to go into sleep time (Unit shut down, freeze
cylinders beaters and refrigeration systems not operating). At start of sleep time, refrigeration compressor will
operate for 30-seconds to pump freon out of freeze cylinders evaporator coils, then No. 1 freeze cylinder will go
into defrost and defrost for 60-seconds. After No. 1 freeze cylinder has defrosted, No. 2 freeze cylinder will go into
defrost and defrost for 60-seconds. At end of No. 2 freeze cylinder defrost, Unit will shut down and go into sleep
time.

''WAKE UP'' (WAKE UP TIME)

''WAKE UP'' (WAKE UP TIME) may be programmed into the Unit to allow Unit to resume normal operation at a
desired time. When programmed wake up time is reached, an alarm will sound for a short duration, then Unit will
resume normal operation.
NOTE: Automatic defrost, sleep time, and wake up time may be used in any combination together or
separately.
4
312026000

Advertisement

Table of Contents
loading

Table of Contents