Programming Worksheets - DSC PowerSeries PC1616 Installation Manual

Version 4.2 na security system
Hide thumbs Also See for PowerSeries PC1616:
Table of Contents

Advertisement

PowerSeries - PC1616/PC1832/PC1864

5.2 Programming Worksheets

Shaded programming sections indicate minimum programming requirements
SIA FAR CP-01 defaults are indicated in gray text.
Keypad Partition /Slot and Function Key Programming
[000] Keypad Enrollment
This must be done at each keypad requiring programming.
[0] Slot address [Valid entries are 0-8 for the partition, 1-8 for the slot. (e.g., to enroll a keypad in partition 3 and slot 1, enter (31)]
[1] Function Key 1 Assignment (Valid entries are 00-33)
[2] Function Key 2 Assignment (Valid entries are 00-33)
[3] Function Key 3 Assignment (Valid entries are 00-33)
[4] Function Key 4 Assignment (Valid entries are 00-33)
[5] Function Key 5 Assignment (Valid entries are 00-33)
Function Key Options:
00 Not used
01 Select Partition 1
02 Select Partition 2
03 Stay Arm
04 Away Arm
05 [*][9] No-Entry Arm
06 [*][4] Chime On / Off
07 [*][6][——][4] System Test
08 [*][1] Bypass Mode
09 [*][2] Trouble Display
10 [*][3] Alarm Memory
ICON / LED Defaults
Full Message Defaults
KEYPAD 1
KEYPAD 2
KEYPAD 3
KEYPAD 4
KEYPAD 5
KEYPAD 6
KEYPAD 7
KEYPAD 8
[001]-[004] Zone Definitions
00 Null Zone (Not Used)
01 Delay 1*
02 Delay 2*
03 Instant*
04 Interior*
05 Interior, Stay/Away*
06 Delay, Stay/Away*
07 Delayed 24 Hour Fire (Hardwired)**
08 Standard 24 Hour Fire (Hardwired)
09 24 Hour Supervisory
10 24 Hour Supervisory Buzzer*
11 24 Hour Burglary*
*For burglary applications only
28
11 [*][5] Access Code Programming
12 [*][6] User Functions
13 Command Output #1 [*][7][1]
14 Command Output #2 [*][7][2]/Sensor Reset
15 Global Stay Arming
16 [*][0] Quick Exit
17 [*][1] Reactivate Stay/Away Zones
18 Global Away Arming
19 Command Output 3 [*][7][3]
20 For Future Use
21 Command Output 4 [*][7][4]
[20] Zone
Partition/
Slot
Assigned
11
00
18
00
00
00
00
00
00
00
00
00
12 24 Hour Holdup*
13 24 Hour Gas*
14 24 Hour Heating*
15 24 Hour Auxiliary*
16 24 Hour Panic*
17 24 Hour Emergency*
18 24 Hour Sprinkler*
19 24 Hour Water*
20 24 Hour Freeze*
21 24 Hour Latching Tamper*
22 Momentary Keyswitch Arm*
23 Maintained Keyswitch Arm*
** For residential fire applications only
WWW.DIYALARMFORUM.COM
22 Global Disarming
23 Bypass Recall
24 Recall Bypass Group
25 For Future Use
26 Time and Date
27 Select Partition 3
28 Select Partition 4
29 Select Partition 5
30 Select Partition 6
31 Select Partition 7
32 Select Partition 8
33 Activate Local PGM
Key 1
Key 2
03
04
03
04
25 Interior Delay*
26 24 Hour Non-alarm*
29 Auto Verified Fire
30 Fire Supervisory
31 Day Zone*
32 Instant Stay/Away*
35 24-hour Bell/Buzzer
36 24 Hour Non-Latching Tamper Zone
37 Night Zone
87
88 Standard 24 Hour Fire (Wireless/
Key 3
Key 4
Key 5
06
14
06
14
Delay 24 Hour Fire (Wireless/Addressable)**
16
16
)**
Addressable