DSC PowerSeries PC1616 Installation Manual page 32

Version 4.2 na security system
Hide thumbs Also See for PowerSeries PC1616:
Table of Contents

Advertisement

PowerSeries - PC1616/PC1832/PC1864
[006] Installer's Code
Default
5555
I_______I_______I_______I_______I
Programmable Output Options
01
Residential Burglary and Fire Bell Output
02
For Future Use
Sensor Reset [*][7][2]
03
2 Wire Smoke Support (PGM 2 only)
04
System Armed Status
05
06
Ready To Arm
07
Keypad Buzzer Follow Mode
08
Courtesy Pulse
System Trouble Output (with Trouble options)
09
System Event [Strobe (with Event options)]
10
System Tamper (all sources: zones, keypad, modules)29
11
12
TLM and Alarm
13
Kissoff Output
14
Ground Start Pulse
Remote Operation (DLS-3 Support)
15
For Future Use
16
17
Away Armed Status
[009] PGM1 and PGM2 Output Programming (Main Panel)
Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
PC1616 and PC1832 have 2 onboard PGMs (PGM 1 and 2). PC1864 has 4 onboard PGMs (PGM 1-4)
Default
19
PGM 1
I_______I_______I
[010] PGM3 to PGM10 Output Programming (Main Panel/PC5208)
Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default
01
PGM 3 (main panel/PC5208)*
I_______I_______I
01
PGM 4 (main panel/PC5208)*
I_______I_______I
01
PGM 5 (PC5208)
I_______I_______I
01
PGM 6 (PC5208)
I_______I_______I
These two sections allow you to program both PGM3 and PGM4 on the main panel, and the first two PGM outputs on the PC5208. If you use
both the main panel and the PC5208 outputs, PGM3 will work the same as the first PC5208 output, and PGM4 will work the same as the sec-
ond PC5208 output.
[011] PGM 11 to PGM 14 Output Programming (PC5204)
Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default
01
PGM 11
I_______I_______I
01
PGM 12
I_______I_______I
Other System Options
[012] Keypad Lockout Options
If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000
Number of Invalid Codes Before Lockout (001-255 codes)
I_______I_______I_______I
000
Lockout Duration (001-255 minutes)
I_______I_______I_______I
30
[007] Master Code
Default
1234
I_______I_______I_______I_______I
18
Stay Armed Status
19
Command Output #1 ([*][7][1])
Command Output #2 ([*][7][2])
20
Command Output #3 ([*][7][3])
21
Command Output #4 ([*][7][4])
22
23
24 Hour Silent Input
24
24 Hour Audible Input
25
Delayed Fire and Burglary Output
26
Battery Test Output
28
Holdup Output
Zone Follower Output (Zones 1-8)
30
Partition Status Alarm Memory
31
Alternate Communicator
32
Open After Alarm
33
Bell Status and Programming Access Output
34
Away Armed with no Zone Bypassed Status
35
Zone Follower Output (Zones 9-16)
Default
01
01
01
01
Default
01
PGM 13
I_______I_______I
01
PGM 14
I_______I_______I
WWW.DIYALARMFORUM.COM
[008] Maintenance Code
Default
AAAA
36
37
38
39
40
41
Default
10
PGM 2
I_______I_______I
PGM 7 (PC5208)
I_______I_______I
PGM 8 (PC5208)
I_______I_______I
PGM 9 (PC5208)
I_______I_______I
PGM 10 (PC5208)
I_______I_______I
I_______I_______I_______I_______I
Zone Follower Output (Zones 17-24
Zone Follower Output (Zones 25-32)
Zone Follower Output (Zones 33-40)
Zone Follower Output (Zones 41-48)
Zone Follower Output (Zones 49-56)
Zone Follower Output (Zones 57-64)
Output types [03] and
[20] cannot be used
together on the same
system.