DSC PowerSeries PC1616 Installation Manual page 18

Version 4.2 na security system
Hide thumbs Also See for PowerSeries PC1616:
Table of Contents

Advertisement

PowerSeries - PC1616/PC1832/PC1864
[5]
For Future Use
[6]
Refer to the PC1616/PC1832/PC1864 Reference Manual for RF Delinquency details.
[7]
Future Use
[8]
ON: When the system is armed in Stay mode, during the Exit delay, the system will sound 1 beep every 3 second.
OFF: When the system is armed in Stay mode, the system will be silent during the Exit delay.
Section [023] Tenth System Option Code
Option
Description
[1]
ON: the keypad [F] emergency key will only beep three times to acknowledge the button has been pressed. The system will not
activate the bell output. OFF: the system will activate the bell output and beep the keypad.
[2]
Refer to the PC1616/PC1832/PC1864 Reference Manual for 200 Baud Open/Close Identifier details.
[3]
ON: the system will only transmit the Test Transmission reporting code if the system is armed at the time the system is programmed
to report the event. OFF: the system will always report the Test Transmission reporting code at the programmed time.
[4]
ON: the system changes the Test Transmission Reporting Cycle Time from Days to Hours. OFF: the Test Transmission Reporting
Cycle Time is in Days.
[5]
ON: the user cannot switch from Away Arm mode to Stay Arm mode using the function keys. OFF: the user can switch arming
modes.
[6]
ON: the system disconnects a listen in/two-way session if a new event occurs.
OFF: the system does NOT disconnect. New events are transmitted only after the session is terminated.
[7]
ON: the system does NOT activate the keypad buzzer for any trouble condition (excluding Fire Troubles). OFF: the system
annunciates troubles via the keypad buzzer (two beeps every 10 seconds) normally.
[8]
ON: Keyswitches will always arm in away mode. OFF: Keyswitches will arm in away mode if an entry/exit zone is violated during
exit delay.
Section [030] Fast Loop Response
This section is used to determine the Loop Response Time for the main panel zones.
ON: the loop response time will be 36 mS. OFF: the loop response time will be 400 mS.
Section [101] to [164] Zone Attributes
These sections are used to customize the operation of the zones. There are 9 toggle options in each Section:
Option
Description
[1]
ON: alarms are audible (bell output). OFF: alarms are silent.
[2]
ON: the bell output is steady (burglary). OFF: the alarm output pulses (fire).
[3]
ON: a zone violation or restoral will activate Chime. OFF: Chime is not activated.
[4]
ON: the user can manually bypass the zone using the [ ][1] command. OFF: the zone cannot be manually bypassed.
[5]
ON: the partition can be armed even if the zone is violated (the zone will not affect the Ready status). OFF: the zone must be
secure before arming.
[6]
ON: the system shuts down alarm reporting after the programmed number of alarms have occurred. OFF: the panel will always
report the event if an alarm occurs.
[7]
ON: the system delays reporting the event for the time programmed for the Transmission Delay time. OFF: the panel
immediately transmits the reporting event when an alarm is detected.
[8]
ON: the zone is a wireless or addressable device. OFF: the zone is a hardwire zone (main panel, zone expander or keypad zone).
16
WWW.DIYALARMFORUM.COM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerseries pc1832Powerseries pc1864Pc1808

Table of Contents