Section [904]: Wireless Placement Test
Enter Section [904] followed by the 2-digit number of the wireless zone to test. When a wireless signal is received from the selected trans-
mitter, the system will indicate the location as Good or Bad as follows:
Good:
One bell squawk, 1 keypad beep, keypad zone light [1] ON
Bad:
Three bell squawks, 3 keypad beeps, keypad zone light [3] ON
Press [#] to exit when testing is complete. Enter the 2-digit zone number for the next wireless device to test or press [#] to return to standard
programming.
Section [990]: Installer Lockout Enable
Enter Section [990][Installer Code][990] to enable the Installer Lockout feature. A hardware default cannot be performed when the
Installer Lockout feature is ON. In addition, the system will chatter the line seizure relay 10 times if the panel is powered up to indicate the
feature is ON.
Section [991]: Installer Lockout Disable
Enter Section [991][Installer Code][991] to turn the Installer Lockout feature OFF.
Section [993] to [999]: Factory Default Module/Panel
The following Sections can be used to factory default a module or the main control panel. Enter the appropriate Section, followed by the
Installer Code, followed by the Section number (E.g., [993][Installer Code][993])
Section [993]:
Section [995]:
Section [996]:
Section [997]:
Section [998]:
Section [999]:
Hardware Reset (Default) Main Control Panel
Perform the following to default the main control panel:
1.
Power down the system completely.
2.
Connect a short between Zone 1 and PGM1 on the control panel (remove all other wires form these terminals).
3.
Power up the control panel (AC power only) for 10 full seconds.
4.
Power down the control panel, remove short between Zone 1 and PGM1.
5.
Power up the control panel.