[3]
ON: the keypad will display the message 'Communications Cancelled' (programmable LCD) or 'CC' (fixed-message LCD) upon
successful transmission of the Communication Cancelled reporting event. OFF: the keypad will not display these messages.
[4]
ON: the system dials the Call Waiting Cancel String on the first attempt to dial the central station. OFF: the system does not dial the Call
Waiting Cancel String.
[5]
ON: enables support for the T-Link module. OFF: disables T-Link.
[6]
ON: the AC Failure Transmission Delay Timer will use hours. OFF: the delay will be in minutes.
[7]
ON: Sets the number of Dialing attempts to 1 when using Residential Dial Format. OFF: Residential Dial follows Dialing Attempt
Counter.
[8]
For Future Use
Section [383] Fourth Communicator Option Code
Option
Description
[1]
ON: Events programmed to communicate to phone #1 will use the Partition Account Number in section [311]. Events Programmed to
communicate to phone #2 will use the Partition Account Number in section [312]. OFF: Each events will use its respective partition
account code.
[2-8]
For Future Use
Section [389] T-Link Fault Check Timer
Program the period of time (in seconds) in between checks to see if the T-Link module is present. Valid entries are [001]-[255].
Section [401] First Downloading Option Code
Option
Description
[1]
ON: the system answers incoming calls for downloading (either Programmed Number of Rings or Double Call). OFF: the system does not
answer incoming calls using the double call routine for downloading.
These settings do not affect the 6 hour DLS downloading window on power up.
[2]
ON: the user can enable downloading for the DLS Window using the [ ][6] command. OFF: the user cannot enable downloading.
[3]
ON: the system will hang up after a successful DLS connection and call the computer back using the DLS Phone Number (Section [402]).
OFF: the system stays connected to the computer.
[4]
ON: the user can initiate a downloading session using the [ ][6] command. OFF: the user cannot initiate a downloading session.
[5]
ON: the system attempts to call the downloading computer after transmitting a Event Buffer 75% Full event to the central station. OFF: the
system does NOT call the downloading computer after transmitting this event.
[6]
ON: Panel communicates with DLS at 300 Baud. OFF: Panel communicates with DLS at 110 Baud.
[7]-[8]
For Future Use
Section [402] Downloading Computer Phone Number
The Downloading Computer Telephone Number is used for Call Back, User Initiated DLS and the Auto Event Buffer Upload functions.
Program the phone number as required. HEX digits can be included for special applications:
HEX [A]
HEX [B]
HEX [C]
HEX [D]
HEX [E]
HEX [F]
Section [403] Downloading Access Code
Program the 6-digit Downloading Access Code. Upon connection, the system will only connect to the downloading computer if the
Downloading Access Code programmed matches the Downloading Access Code programmed in the computer file.
Not used
Simulates a [ ] key press
Simulates a [#] key press
Additional dial tone search
2-second pause
End of phone number marker
WWW.DIYALARMFORUM.COM
Section 4 – Programming Descriptions
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerseries pc1832Powerseries pc1864Pc1808

Table of Contents