ON: auto-arming schedules (Program Sections [181]-[188]) will be available to the user in the [ ][6] menu.
OFF: auto-arming schedules will NOT be available to the user in the [ ][6] menu.
[6]
ON: the Audible Exit Fault feature will be enabled. If a delay zone is not secured correctly and not force-armed, at the end of the exit delay,
the system will go into entry delay and turn ON the bell output. The bell will also sound if the delay zone is opened within 10 seconds of the
exit delay timeout. OFF: the keypad will sound the entry delay through the keypad as normal.
[7]
ON: the system will NOT log additional alarms for a zone that has reached the swinger shutdown threshold.
OFF: all zone alarms will be logged.
[8]
ON: Temporal Three Fire Signal is used to annunciate fire alarms
(½ second ON, ½ second OFF, ½ second ON, ½ second OFF ½ second ON, 1 ½ seconds OFF).
OFF: the system will pulse the bell output
(½ second ON, ½ second OFF).
Section [014] Second System Option Code
Option
Description
[1]
ON: the system squawks the bell output once when a partition is armed, twice when disarmed. OFF: the bell output does not
activate. Refer to section [017] option 8.
[2]
ON: the system squawks the bell output every 10 seconds during the auto-arm pre-alert. OFF: the bell output does not activate.
[3]
ON: the system will squawk the bell output once every second during Exit Delay, 3 squawks per second for the last 10 seconds.
OFF: the bell output will not activate.
[4]
ON: the system will squawk the bell output once every second during Entry Delay, 3 squawks per second for the last 10 seconds.
OFF: the bell output will not activate.
[5]
ON: the system squawks the bell output once every 10 seconds when a trouble condition is present.
OFF: the bell output does not activate.
[6]
ON: the system will beep the keypads once every second, and 3 times a second during the last 10 seconds, during exit delay when
the system is armed with a user code or armed in the Away mode. OFF: the keypads will not beep.
[7]
ON: the exit delay will be terminated (reduced to 5 seconds) when a Delay 1 zone is violated and restored after the system is armed.
OFF: the exit delay will count down as normal.
[8]
ON: the bell output will not timeout if a fire alarm occurs. The user must turn OFF the bell by entering a valid user code.
OFF: the bell output will timeout normally.
Section [015] Third System Option Code
Option
Description
[1]
ON: the keypad [F] fire emergency key will be enabled. OFF: the keypad [F] fire emergency key will be disabled.
[2]
ON: the keypad [P] panic emergency will be audible (bell output). OFF: the keypad [P] emergency key will be silent.
[3]
ON: the Quick Exit feature will be enabled. OFF: the Quick Exit feature will be disabled.
[4]
ON: the Quick Arming [ ][0] feature will be enabled. OFF: Quick Arming [ ][0] feature will be disabled.
If this feature is disabled, a valid user code must be entered after the Stay or Away function buttons are pressed.
[5]
ON: a valid user code must be entered after pressing [ ][1] to access the Bypass feature. OFF: a user code is not required.
[6]
ON: the Master Code (user code 40) can only be changed in Installer Programming. OFF: the Master Code can be changed using
the User Programming [ ][5] command.
[7]
ON: the system supervises the telephone line and displays a trouble if disconnected. OFF: the telephone line is not supervised.