Flame & Temperature Adjustment; Flame Characteristics - Vermont Castings Radiance RADVTCB Homeowner's Installation And Operating Manual

Direct vent gas heater
Table of Contents

Advertisement

Radiance Direct Vent Gas Heater
Pilot As-
sembly
Fig. 54 Pilot Assembly location.
Follow regular maintenance procedures as described
on Page 41.
Flame & Temperature Adjustment
For stoves equipped with HI/LO valves, flame adjust-
ment is accomplished by rotating the HI/LO adjustment
knob located near the center of the gas control valve.
(Fig. 55)
RADVTC Series
(Comfort Control Models)
Fig. 56 Correct pilot and burner flame appearance.
3030
ST477
Stardance
pilot location
10/4/00
PSE
Pilot
Turn
counterclockwise
to increase
flame height
Fig. 55 Flame adjustment knob for SIT valve.
ST476
It is important to periodically perform a visual check
of the pilot and the burner flames. Compare them to
Figure 56. If any of the flames appear abnormal, call a
service person.
SIT Pilot
CO105d
Pilot flame
6/07 djt
�����
Turn clockwise

Flame Characteristics

FP390
FLAME ADJUSTMENT KNOB
11/21/96
RADVT Series
CO105d
LG491
to decrease
flame height
20012697