Operation; Your First Fire; Pilot And Burner Inspection; Flame & Temperature Adjustment - Vermont Castings 0003380 Operating Manual

Table of Contents

Advertisement

The Radiance is shipped with the operable door front
plate. The stove may be operated with the doors either
open or closed. To open the front doors, insert the
handle provided into the door latch stub and turn it to
the right and up. (Fig. 27) When not in use, the handle
may be stored in the handle holder on the right side of
the rear shroud. (Fig. 28)
ST621
Fig. 27 To open the front doors, turn handle counterclockwise.
RADIANCE
ST621
Fig. 28 When not in use, store handle in the handle holder.
Radiance

Your First Fire

operable doors
Read these instructions carefully and familiarize your-
1/31/01
self with the burner controls shown on Page 17. Locate
the pilot assembly, Figure 29. Follow the lighting instruc-
tions on Page 16 exactly.
During the first fire, it is not unusual to smell some odor
associated with new logs, paint and metal being heated.
Odors should dissipate within the first eight to ten hours,
however, you can open a window to provide fresh air to
alleviate the condition.

Pilot and Burner Inspection

Each time you light your heater check that the pilot
flame and burner flame patterns are as shown in Figure
31 and Figure 32. If flame patterns are incorrect, turn
the heater off. Contact your dealer or a qualified gas
technician for assistance. Do not operate the heater
until the pilot flame is correct.
Flame & Temperature Adjustment
For units equipped with HI/LO valves, the flame adjust-
ment is accomplished by rotating the HI/LO adjustment
knob located near the center of the gas valve. (Fig. 30)
30005056
Counterclockwise
to Open
Clockwise
to Close
Handle
Holder
ST624
handle holder
2/6/01

Operation

Fig. 29 Pilot assembly location.
Turn
counterclockwise
to increase
flame height
Fig. 30 Flame adjustment knob for SIT valve.
It is important to periodically perform a visual check
of the pilot and burner flames. Compare them to the
illustration below. (Fig. 31, 32) If the flame patterns ap-
pear abnormal, contact a qualified service provider for
ST656
service and adjustment.
Fig. 31 Correct pilot flame appearance. OP pilot.
Fig. 32 Correct burner flame pattern.
Radiance® Vent-Free Gas Heater
Natural
Pilot
LP Pilot
ST673
RUVSOD
Pilot assembly location
7/249/01 djt

Flame Characteristics

FP390
FLAME ADJUSTMENT KNOB
11/21/96
ST198
pilot flame detail
11/99
LG155
Radiance logs
installed
ST673
Turn clockwise
to decrease
flame height
ST198
Red Glow
LG173
15