60Hz - Daikin SkyAir Super Inverter 70 D Series Service Manual

Split system air conditioners d series;
Table of Contents

Advertisement

Specifications
1.2

60Hz

FHYCP (Ceiling Mounted Cassette Type)
Indoor Units
Model
Outdoor Units
1 Cooling Capacity (1)/(2)
1 Heating Capacity (1)/(2)
Indoor Units
Dimensions
H×W×D
Type
Coil
Row×Stages×Fin Pitch
Face Area
Model
Type
Fan
Motor Output
Air Flow Rate
Air Filter
Machine Weight
Liquid
Piping
Gas
Connections
Drain
Wired
Remote Controller
(Option)
Wireless
Model
Color
Decoration
Dimensions (H×W×D)
Panel (Option)
Air Filter
Weight
Outdoor Units
Color
Dimensions
H×W×D
Type
Coil
Row×Stages×Fin Pitch
Face Area
Model
Comp.
Type
Motor Output
Model
Type
Fan
Motor Output
Air Flow Rate
Machine Weight
Liquid
Piping
Gas
Connections
Drain
Safety Devices
Capacity Control
Refrigerant Control
Max. Length
Ref.Piping
Max. Height Difference
Model
Refrigerant
Charge
Model
Ref. Oil
Charge
Drawing No.
Notes:
1. Nominal capacities are based on the following conditions:
2. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
3. In case of drain piping for outdoor unit, drain piping kit (option) is needed.
18
FHYCP71DVL
RZP71DVAL
kW
(3.3~8.1) / (3.4~8.2)
24,200 / 24,500
Btu/h
(11,200~27,600) / (11,600~27,900)
6,100 / 6,100
kcal/h
(2,800~6,900) / (2,900~7,000)
kW
(3.5~9.0) / (3.5~9.0)
27,300 / 27,300
Btu/h
(11,900~30,700) / (11,900~30,700)
6,800 / 6,800
kcal/h
(3,000~7,700) / (3,000~7,700)
FHYCP71DVL
mm
246×840×840
QTS46D14M
Turbo Fan
W
m³/min.
(H) 19
kg
φ
mm
φ
mm
15.9 (Flare)
φ
mm
I. D
BRC1C61
BRC7E61W
BYCP125D-W1
mm
45×950×950
Resin Net (with Mold Resistant)
kg
RZP71DVAL
Pale Ivory
mm
905×900×320
2YC63AXD
Hermetically Sealed Swing Type
kW
P47M11F
W
m³/min.
kg
φ
mm
φ
mm
15.9 (Flare)
φ
mm
m
50 (Equivalent Length 70m)
m
kg
3.2 (Charged for 30m)
DAPHNE FVC50K
L
Mark
Cooling
Indoor: 27˚CDB, 19.0˚CWB
(1)
Outdoor: 35˚CDB, 24˚CWB
Indoor: 27˚CDB, 19.5˚CWB
(2)
Outdoor: 35˚CDB, 24˚CWB
7.1 / 7.2
8.0 / 8.0
Cross Fin Coil (Waffle Louver Fins and N-hix Tubes)
2×10×1.2
0.454
30
(L) 14
24
9.5 (Flare)
φ
25×O. D
32
White
5.5
Cross Fin Coil (Waffle Fins and NHi-XA Tubes)
2×40×1.4
0.991
1.9
Propeller
55
53
71
9.5 (Flare)
26.0 (Hole)
High Pressure Switch. Fuse.
Compressor Revolution Speed Control (Inverter System)
Expansion Valve (Electronic Type)
30
R-407C
0.65
4D034046
Heating
Indoor: 20˚CDB, 15˚CWB
Outdoor: 7˚CDB, 6˚CWB
Indoor: 21˚CDB, 15˚CWB
Outdoor: 7˚CDB, 6˚CWB
FHYCP100DVL
RZP100DVAL
10.0 / 10.1
(5.0~11.4) / (5.1~11.6)
34,100 / 34,400
(17,000~38,900) / (17,400~39,600)
8,600 / 8,600
(4,300~9,800) / (4,300~9,900)
11.2 / 11.2
(5.6~12.8) / (5.6~12.8)
38,200 / 38,200
(19,100~43,600) / (19,100~43,600)
9,600 / 9,600
(4,800~11,000) / (4,800~11,000)
FHYCP100DVL
288×840×840
2×12×1.2
0.544
QTS46C17M
Turbo Fan
120
(H) 26
(L) 21
28
φ
9.5 (Flare)
φ
19.1 (Flare)
φ
φ
I. D
25×O. D
32
BRC1C61
BRC7E61W
BYCP125D-W1
White
45×950×950
Resin Net (with Mold Resistant)
5.5
RZP100DVAL
Pale Ivory
1,435×900×320
2×64×1.4
1.598
JT100FA-VD
Hermetically Sealed Scroll Type
1.9
P47M11F×2
Propeller
55+55
97
119
φ
9.5 (Flare)
φ
19.1 (Flare)
φ
26.0 (Hole)
70 (Equivalent Length 90m)
30
R-407C
5.0 (Charged for 30m)
DAPHNE FVC68D
1.2
Conversion Formulae
Piping length
kcal/h=kW×860
Btu/h=kW×3414
7.5m
cfm=m³/min×35.3
(Horizontal)
5m
(Horizontal)
Specifications
SiE25-110

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Skyair super inverter 70Skyair r-407c