Su Board Isolation Procedure - Panasonic TC-P42X1 Revised Troubleshooting Handbook

Plasma hd and fhd tv
Hide thumbs Also See for TC-P42X1:
Table of Contents

Advertisement

If the power LED continues to blink even after the TV is unplugged, press and hold the power
switch on the TV for a few seconds until the LED turns off.
To isolate the SU board:
1.
Remove the 2 VF_GND screws on the
SU board only.
2.
Unplug connector SC41 on the SC
board and SU11 on SU board.
3.
Place SC jig cable ZSC09187)between
pins 1 and 2 of connector SC50 on the
SC board.
Note: If the SC jig is not available, install a
jumper between pins 1 and 2 of
connector SC50 on the SC board.
(Remove the jig or jumper after
completing isolation procedure)
Note: This procedure could be useful when
troubleshooting 7 blinks problems.

SU Board Isolation Procedure

Slide #21