A Appendices
Parameters
Characters
pfd5
Monitor/Setting Item 5
000
spd1
PV/SP No. 1 Display
Selection
spd2
PV/SP No. 2 Display
Selection
odsl
MV Display Selection
pvdp
PV Decimal Point
000
Display
pvst
PV Status Display
Function
svst
SV Status Display
Function
d.ref
Display Refresh Period
lcmt
LCT Cooling Output
*8
Minimum ON Time
cmoV
Move to Calibration
000
Level
*1
If the Manual MV Limit Enable parameter is set to ON, the setting range will be the MV lower limit to the
MV upper limit.
*2
The setting ranges are different for relay and voltage outputs (for driving SSR) and for linear current
outputs.
*3
This parameter can be set when the Program Pattern parameter is set to OFF, but the function will be
disabled.
*4
WR1 to WR8 are not displayed when the logic operation function is not used.
*5
With the E5CC-U or E5GC, if the control output is a linear current output, the control output can be used
as a simple transfer output. (The E5CC-U must be manufactured in May 2014 or later (version 2.2 or
higher).)
*6
Seconds can be selected only with the E5GC.
*7
WR (status display message) can be selected only with the E5GC.
*8
This parameter is not supported for E5CC, E5EC, and E5AC version 2.0 or lower.
A - 30
Setting (monitor) value
Same as Monitor/Setting Item 1.
0: Nothing is displayed.
1: PV/SP/Nothing displayed
2: PV/Nothing displayed/Nothing displayed
3: SP/SP (character display)/Nothing displayed
4: PV/SP/MV (valve opening for
Position-proportional Models)
5: PV/SP/Multi-SP No.
6: PV/SP/Soak time remain
7: PV/SP/Internal SP (ramp SP)
8: PV/SP/Alarm value 1
Same as PV/SP No. 1 Display Selection.
O: MV (Heating)
C-O: MV (Cooling)
OFF, ON
OFF: OFF
MANU: Manual
STOP: Stop
ALM1: Alarm 1
ALM2: Alarm 2
ALM3: Alarm 3
ALM4: Alarm 4
ALM: OR of alarms 1 to 4
HA: Heater alarm
*7
WR: Status display message
OFF: OFF
MANU: Manual
STOP: Stop
ALM1: Alarm 1
ALM2: Alarm 2
ALM3: Alarm 3
ALM4: Alarm 4
ALM: OR of alarms 1 to 4
HA: Heater alarm
*7
WR: Status display message
OFF, 0.25, 0.5, 1.0
0.1 to 1.0
−1999 to 9999
Display
Default
0
*6
4
0
o
c-o
,
0
off
on
,
ON
off
OFF
manu
stop
alm1
alm2
alm3
alm4
alm
ha
wr
off
OFF
manu
stop
alm1
alm2
alm3
alm4
alm
ha
wr
off, 0.25,
0.25
0.5, 1.0
0.2
0
E5@C Digital Temperature Controllers User's Manual (H174)
Unit
None
None
None
None
None
None
None
Second
Second
None