4

GENERAL INFORMATION

Nominal heat
Oil consumption **
output
max speed
34,130 BTU/hr
.275 US gal/hr .055 US gal /hr
10 kW
1.25 litre/h
**
1 pint = 0.568 261 litre
1 litre = 1.760 pints
Pints, quarts and gallons are Canadian unless otherwise noted.
To determine the flow rate, disconnect the feed line from the carburetor to the burner. Place the container for measuring
the calibration under the carburetor outlet.

CARE OF ENAMELLED PARTS

Do not use abrasive cleaners to clean these parts. Buff lightly with a clean, dry cloth. Porcelain enamel compo-
nents must be handled with care. The baked-on finish is "glasslike". If struck, it will chip. Touch-up paint is
available through your Napoleon dealer.

CARE OF GLASS

If the glass is not kept clean permanent discolouration and / or blemishes may result. Normally a hot burn will
clean the glass. The most common reason for dirty glass is running the unit at a low burning rate. If it is
necessary to clean the glass, use a soft cloth with a nonabrasive cleaner. Coarse cleaning materials may cause
scratches or otherwise damage the glass. Scratches can develop into cracks or breaking of the glass. DO NOT
CLEAN GLASS WHEN HOT!
The glass is very strong and comes in strips for maximum performance. However, always close the door gently.
If the glass should ever crack while the fire is burning, do not open the door until the fire is out and do not
operate the stove again until the glass has been replaced with new borosilicate glass, available from your
Napoleon / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MATERIALS. Check gaskets and seals regularly.

INSTALLATION

SPECIFICATIONS
16" (402mm)
15" (383mm)
21½" (544mm)
WARNING: Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. Refer to this manual. For assistance or additional infor-
mation consult a qualified installer, service agency or the oil supplier.
min speed
¼ litre/h
1 ml = 0.001 760 pint
1 quart = 1.136 522 litres
1 litre = 0.879 877 quart
5"ø (ø125mm)
20" (505mm)
Chimney draft required
max speed
min speed
20 Pa
6 Pa
@ .08 w.c.g
@.024 w.c.g.
1 gallon = 4.546 090 litres
1 litre = 0.22 gal
2
4
½
"
(620mm)
Weight
Flue outlet
outside diameter
260 lbs
5 inches
118 kg
120-125 mm
1 US gal = 3.785 412 litres
FIGURE 1
27" (678mm)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents