Napoleon 1600C-1 Installation And Operation Instructions Manual

Napoleon 1600C-1 Installation And Operation Instructions Manual

Listed solid fuel burning space heater
Table of Contents

Advertisement

Available languages

Available languages

INSTALLER : THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PARTICULATE
EMISSION STANDARDS BY E.E.M.C. THESE STOVES HAVE BEEN TESTED AND LISTED BY WARNOCK HERSEY LTD. TO STANDARDS : UL 1482 / ULC-S627.
MODEL 1600C-1 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.
INSTALLATION AND OPERATION INSTRUCTIONS FOR
LISTED SOLID FUEL BURNING SPACE HEATER
MODEL : 1600C-1
WARNING :
Please read this entire manual before you install and use your new room heater. Failure to follow
instructions may result in property damage, bodily injury, or even death.
If this stove is not properly installed, a house fire may result.
FOR YOUR SAFETY :
Follow the installation directions. This stove can be very hot when burning. Combustible materials such as firewood,
wet clothing, etc. placed too close can catch fire. Children and pets must be kept from touching the stove when it is
hot. The chimney must be sound and free of cracks. Before installing this unit, contact the local building or fire
authority and follow their guidelines.
Operate only with door tightly closed. The door must be kept closed during operation to prevent smoke, embers
from entering the room. Burn wood directly on cast grate supplied. Do not elevate the fire. An opening of at least 14
square inches (90 sq.cm.) of outside air must be admitted to the room. This stove is designed to burn natural wood
only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as
compared to softwoods or too green or freshly cut hardwoods. Do not start a fire with chemicals or fluids such as
gasoline, engine oil, etc. Do not burn treated wood, coal, charcoal, coloured paper, cardboard, solvents or garbage
which tend to produce more pollution than wood. Do not let the stove become hot enough for any part to glow red.
KEEP THE STOVE TOP TEMPERATURE BELOW 700 °F (371 °C). Attempts to achieve heat output rates that
exceed stove design specifications can result in metal distortion and damage.
Wolf Steel Ltd., 24 Napoleon Rd.,
Barrie, ON., Canada L4M 4Y8 (705)721-1212
Fax : (705)722-6031
www.napoleonfireplaces.com
Email : ask@napoleon.on.ca

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon 1600C-1

  • Page 1 Follow the installation directions. This stove can be very hot when burning. Combustible materials such as firewood, wet clothing, etc. placed too close can catch fire. Children and pets must be kept from touching the stove when it is hot. The chimney must be sound and free of cracks. Before installing this unit, contact the local building or fire authority and follow their guidelines.
  • Page 2 NAPOLEON wood fireplaces are manufactured under the strict Standard of the World Recognized NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON.
  • Page 3: Table Of Contents

    7 p. 7 STOVE MAINTENANCE p. 7 Creosote formation and removal Runaway or chimney fire ORDERING PROCEDURES MODEL 1600C-1 681 X 615 mm 712 mm 698 mm 304 X 520 X 265 mm 41.3 L 56-112 m 50,000 Btu...
  • Page 4: Introduction

    Principal of operation The 1600C-1 is designed to be operated with the door closed. The heat produced is mainly transmitted through the window and the body of the unit. Combustion occurs on the grate with a draft entry through the top of the combustion chamber.
  • Page 5: Installation

    6. Alcove installation Model 1600C-1 may be installed into an alcove having a depth of not more than 4 feet and a height of at least 7 feet, when using a listed double wall connector that is rated for a minimum 12”...
  • Page 6: Alcove Installation

    NFPA 211or CAN/CSA-B365. Alcove installation Model 1600C-1 may be installed into an alcove having a depth of not more than 4 feet and a height of at least 7 feet, when using a listed double wall connector that is rated for a minimum 12”...
  • Page 7: Adding Chimney Sections

    Chimney connection A 6” diameter single wall stove pipe, used to connect the stove to the chimney, must be installed with the crimped end toward the stove. This will ensure that the moisture which condenses from the burning wood will flow back into the fire chamber.
  • Page 8: Mobile Home Installation

    113KT 1600C-1 Adaptor Kit Intallation When installing the 1600C-1 in a mobile home,use the 111KT Outside air kit in conjunction with the 113KT Outside Air Adaptor Kit.
  • Page 9: Operating Instructions

    When lit for the first time The stove will emit a slight odour for a few hours. This is a normal temporary condition caused by the “burn-in” of internal paints and lubricants used in the manufacturing process and will not occur again.
  • Page 10: Fire Extinguishers / Smoke Detectors

    This means the firebox temperature is too low. EP90-K OPTIONAL SCREEN KIT The 1600C-1 may only be operated with the doors open when spark screen EP90-K is used and installed properly. This kit is not applicable for mobile homes.
  • Page 11: Wood Pile Maintenance

    If necessary spray with a fire extinguisher or water from a garden hose. 4. Do not operate the stove again until you are certain the chimney and its lining have not been damaged.
  • Page 12: Ordering Procedures

    ORDERING PROCEDURES Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information : 1. Model & Serial Number of fireplace 2.
  • Page 13 N° Code Description....P ..N ..F . . . Qty 301172 Ash pan door ........F ..01 301172 Ash pan door.
  • Page 15 DE LA QUALITÉ DE L’ENVIRONNEMENT (D.E.Q.) LES NORMES D’ÉMISSION DE PARTICULES DE E.E.M.C. CE POÊLE A ÉTÉ TESTÉ ET HOMOLOGUÉ PAR WARNOCK HERSEY LTÉE SELON LES NORMES UL 1482 / ULC-S627. LE MODÈLE 1600C-1 A ÉTÉ TESTÉ ET HOMOLOGUÉ POUR INSTALLATION LES MAISONS MOBILES. INSTRUCTIONS D’INSTALLATION ET D’OPÉRATION POUR LES APPAREILS DE CHAUFFAGE LOCALISÉ...
  • Page 16 Les poêles au bois NAPOLEON sont fabriqués conformément aux normes strictes du certificat d’assurance de qualité Les produits NAPOLEON sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifiés qui sont fiers de leur travail. Le poêle entier est soigneusement inspecté par un technicien qualifié...
  • Page 17 7 Formation et enlèvement de créosote p. 7 Feu de cheminée ou feu hors contrôle p. 8 REMPLACEMENTS p. 8 MODÈLE 1600C-1 681 X 615 mm 712 mm 698 mm 304 X 520 X 265 mm 41.3 L 56-112 m...
  • Page 18: Introduction

    : Le “1600C-1” est un appareil de chauffage au bois à f o n c t i o n n e m e n t c o n t i n u a y a n t u n e c h a m b r e d e combustion fermée avec parois en fonte où...
  • Page 19: Installation

    Pour les dégagements avec le kit EP63 installé, se référer à la page 6. Installation dans une alcôve modèle 1600C-1 peut être installé dans une alcôve de profondeur inférieure à 122 mm et d’une hauteur d’au moins 213 mm, équipé d’un conduit mural double enveloppe homologué...
  • Page 20: Installation Avec Le Kit Soufflerie Ep63

    Les installations avec des dégagements réduits doivent se conformer aux normes NFPA211 ou CAN/CSA-B365. Installation dans une alcôve modèle 1600C-1 peut être installé dans une alcôve de profondeur inférieure à 122 mm et d’une hauteur d’au moins 213 mm, équipé d’un conduit mural double enveloppe homologué...
  • Page 21: Ajout De Sections De Cheminée

    Raccordement de la cheminée Un conduit de raccordement à paroi simple de 6" de diamètre utilisé pour raccorder le poêle à la cheminée doit être installé avec l’extrémité gaufrée (partie mâle) sur la buse du poêle. Ceci permettra à l’humidité du bois en combustion de retourner dans la chambre de combustion.
  • Page 22: L'évacuation

    être aspirées dans la pièce. Adaptateur pour prise d’air extérieur 113KT Lorsque vous installez le 1600C-1 dans une maison mobile, utilisez l’ensemble de prise d’air extérieur 111KT conjointement avec l’adaptateur pour prise d’air extérieur 113KT.
  • Page 23: Instructions D'opération

    INSTRUCTIONS D’OPÉRATION AVERTISSEMENT : Objects placed in front of the fire place should be kept a minimum of 48” from the front face. ATTENTION : N’utilisez jamais d’essence, d’huile à lampe, de kérosène, d’essence à briquets ou autres liquides similaires pour allumer ou raviver un feu dans cet appareil.
  • Page 24: Extincteurs Et Détecteurs De Fumée

    à feu est trop basse. Pare-étincelles optionnel EP90K Lorsque vous utilisez le pare-étincelles EP90-K, le poêle 1600C-1 doit fonctionner avec les portes ouvertes. Ce pare-étincelles ne peut être utilisé dans des maisons mobiles.
  • Page 25: Entretien Du Tas De Bois

    ENTRETIEN DU TAS DE BOIS Brûlez seulement du bois non peint, propre et bien sec. Il produit plus de chaleur et moins de suie ou de créosote. Fraîchement coupé le bois contient 50% d’humidité tandis qu’après un séchage approprié seulement 20% de l’eau reste.
  • Page 26: Remplacements

    REMPLACEMENTS Contactez votre détaillant ou l’usine concernant les questions de prix et politiques relatives aux pièces de remplacement. Normalement, toutes les pièces peuvent être commandées par votre détaillant ou le distributeur NAPOLÉON. Lorsque vous commandez des pièces de remplacement, précisez toujours l’information suivante : 1.
  • Page 27 N° Code Description....P ..N ..F . . . Qty 301172 Porte cendrier ........F ..01 301172 Porte cendrier .

Table of Contents