Carrier Infinity ICS 58MVC 100 Series Installation Instructions Manual page 59

Direct vent 4-way multipoise condensing gas furnace
Hide thumbs Also See for Infinity ICS 58MVC 100 Series:
Table of Contents

Advertisement

Table
12 - Gas Rate cu Ft/Hr
SECONDS
SIZE OF TEST DIAL
SECONDS
FOR 1
1
2
5
FOR 1
REVOLUTION
REVOLUTION
cu _.
cu _.
cu _.
10
360
720
1800
50
11
327
655
1636
51
12
300
600
1500
52
13
277
555
1385
53
14
257
514
1286
54
15
240
480
1200
55
16
225
450
1125
56
17
212
424
1059
57
18
200
400
1000
58
19
189
379
947
59
20
180
360
900
60
21
171
343
857
62
22
164
327
818
64
23
157
313
783
66
24
150
300
750
68
25
144
288
720
70
26
138
277
692
72
27
133
267
667
74
28
129
257
643
76
29
124
248
621
78
30
120
240
600
80
31
116
232
581
82
32
113
225
563
84
33
109
218
545
86
34
106
212
529
88
35
103
206
514
90
36
100
200
500
92
37
97
195
486
94
38
95
189
474
96
39
92
185
462
98
40
90
180
450
100
41
88
176
439
102
42
86
172
429
104
43
84
167
419
106
44
82
164
409
108
45
80
160
400
110
46
78
157
391
112
47
76
153
383
116
48
75
150
375
120
49
73
147
367
SIZE OF TEST DIAL
1
2
5
cu _.
cu _.
cu _.
72
144
360
71
141
355
69
138
346
68
136
340
67
133
333
65
131
327
64
129
321
63
126
316
62
124
310
61
122
305
60
120
300
58
116
290
56
112
281
54
109
273
1
U
53
106
265
51
103
257
50
100
250
48
97
243
47
95
237
46
92
231
45
90
225
44
88
220
43
86
214
42
84
209
41
82
205
40
80
200
39
78
196
38
76
192
38
75
188
37
74
184
36
72
180
35
71
178
35
69
173
34
68
170
33
67
167
33
65
164
32
64
161
31
62
155
30
60
150
Set Temperature
Rise
UNIT
DAMAGE
HAZARD
Failure
to follow
this caution
may
result
in component
damage.
Temperature
rise must
be within
limits specified
on unit
rating
plate. Operation
is within
a few degrees
of midpoint
of rise range when setup switch
SWI-4
is OFF.
Furnace
must operate
within
ranges
of temperature
rise specified
on the
furnace
rating
plate.
Determine
air temperature
rise as
follows:
1. Place thermometers
in return and supply
ducts as near fur-
nace as possible.
Be sure thermometers
do not see heat ex-
changer
so that radiant
heat does not affect readings.
This
practice
is particularly
important
with straight-run
ducts.
2. When
thermometer
readings
stabilize,
subtract
return-air
temperature
from supply-air
temperature
to determine
air
temperature
rise.
NOTE:
Temperature
rise
can be
determined
for
low-heat
operation
by placing
setup switch
SWI-2
on furnace
control
in
ON
position.
Temperature
rise
can
be
determined
for
medium-heat
operation
by
placing
setup
switch
SW4-2
on
furnace
control
in ON position.
For high-heat
operation,
place
setup switch
SWl-2
and SW4-2
in OFF position
and jumper
R-W2
on furnace
control.
DO NOT forget to return setup switch
to OFF position
and remove
R-W2
jumper
upon completion
of
testing.
(See Fig. 33 for switch and terminal
location.)
3. This furnace
is capable
of automatically
providing
proper
airflow
to maintain
the temperature
rise within
the range
specified
on furnace rating plate. If temperature
rise is out-
side this range, proceed
as follows:
a. Check gas input for low-, medium-,
and high-heat
oper-
ation.
b. Check derate for altitude if applicable.
c. Check all return and supply ducts for excessive
restric-
tions causing
static pressure
greater
than 0.5-in.
wc.
d. Ensure Low Heat Rise Adjust switch SWI-3
on furnace
control
is in ON position
when
a bypass
humidifier
is
used. (See Fig. 33 for switch
location.)
e. Check Troubleshooting
Guide for Variable-Speed
Step
Modulating
Condensing
Furnaces.
Set Thermostat
Heat Anticipator
When
using
a non-electronic
thermostat,
the
thermostat
heat
anticipator
must be set to match
the amp draw of components
in
59