Carrier INFINITY ICS 58MVC Product Data

Carrier INFINITY ICS 58MVC Product Data

100 series deluxe 4-way multipoise variable-speed multi-stage condensing input rates: 60,000 thru 120,000 btuh
Hide thumbs Also See for INFINITY ICS 58MVC:

Advertisement

INFINITYt ICS MODEL 58MVC
DELUXE 4---WAY MULTIPOISE VARIABLE ---SPEED
MULTI---STAGE CONDENSING GAS FURNACE
Series 100 Input Rates: 60,000 thru 120,000 Btuh
Product Data
IdealComfortt technology, the ultimate in
heating comfort . . .
The Carrier Infinityt ICS with IdealComfortt technology
achieves the optimum combination of comfort and efficency.
The Infinityt ICS achieves industry- -leading ultra- -high efficiency
at up to 95 percent Annual Fuel Utilization Efficiency (AFUE).
Efficient performance is enhanced through the variable- -speed
design. To optimize heating performance,
automatically adjusts the heating level, maximizing the use of low
heating levels that produce near silent furnace operation while
meeting the exact heating needs. This unit is designed to keep the
indoor temperature within less than 1 degree of the thermostat
setpoint. Because it operates in low heat most of the time, the
Infinityt ICS uses up to 80% less power than single- -capacity
furnaces.
In addition to providing ultimate comfort, the Infinityt ICS has a
sealed combustion system. This system brings combustion air to
the furnace and vents flue gases outside the furnace in a safe
manner. Because it is sealed, operational noise is minimal. A sealed
combustion system also means fewer cold drafts and less air
infiltration.
Quality materials are the key behind the Infinityt ICS's
outstanding performance. Carrier stands behind quality. We offer
lifetime warranty protection* on the heat exchangers, the heart of
the Infinityt ICS. The rest of the furnace is backed by a limited
5- -year warranty.
The Infinityt ICS is available in 5 heat/airflow combinations. The
A05069
unit has a 4- -way multipoise design and can be installed in upflow,
downflow, or horizontal positions covering up to 20 different
applications. The Infinityt ICS can be vented as a
vent/2- -pipe furnace or as an optional ventilated combustion air
application.
The versatile 4- -way multipoise design in conjunction with variable
speed makes the Infinityt ICS ideal for use with split system
cooling, including 2- -speed units. A Carrier Infinityt
humidifier, comfort ventilator, and Infinityt Zone control will
provide year round comfort and efficiency.
Designed for durability, comfort, and reliability, the Infinityt ICS
is the ultimate in versatile, efficient comfort.
Carrier Infinityr System — When the Infinityt ICS
variable- -speed gas furnace is matched with the Infinityt Control
(- -B release is compatible) and an air conditioner or heat pump, the
homeowner will experience the ultimate in IdealComfortt and
IdealHumidityt through unparalleled control of temperature,
humidity, indoor air quality, and zoning. The Carrier Infinityt
System also provides unprecedented ease of use through onscreen,
text- -based service reminders and equipment malfunction alerts.
1
IdealComfortt
Direct
air purifier,

Advertisement

Table of Contents
loading

Summary of Contents for Carrier INFINITY ICS 58MVC

  • Page 1 IdealComfortt and IdealHumidityt through unparalleled control of temperature, humidity, indoor air quality, and zoning. The Carrier Infinityt System also provides unprecedented ease of use through onscreen, text- -based service reminders and equipment malfunction alerts.
  • Page 2 When installed as a part of the system, this propane gases. The furnace is factory- -shipped for use with natural cabinet allows for easy and convenient addition of a Carrier high gas. A C.S.A. listed gas conversion kit is required to convert efficiency air filter.
  • Page 3: Furnace Components

    FURNACE COMPONENTS A07609 1. Combustion- -air intake connection to ensure contaminant- - 11. Serpentufft secondary condensing heat exchanger (inside). free air (right or left side). Wrings out more heat through condensation. Constructed with polypropylene- -laminated steel to ensure durability. 2. Burner sight glass for viewing burner flame. 12.
  • Page 4: Model Number Nomenclature

    Media Filter Cabinet included Input Rates 060 --- 60,000 Btuh 080 --- 80,000 Btuh 100 --- 100,000 Btuh 120 --- 120,000 Btuh CARRIER ACCESSORIES UNIT SIZE DESCRIPTION PART NO. 060---14 080---14 080---20 100---20 120---20 2---in. — KGAVT0101BRA Vent Termination Kit (Bracket Only for 2 Pipes) 3---in.
  • Page 5 CARRIER ACCESSORIES (CONTINUED) UNIT SIZE DESCRIPTION PART NO. 060---14 080---14 080---20 100---20 120---20 Natural---To---Propane Gas Conversion Kit (Single Kit)* KGANP4301STM Propane---To---Natural Gas Conversion Kit (Single Kit) KGAPN3601STM ECM Motor Simulator (simulates the ECM motor to aid KGASD0301FMS troubleshooting Door Gasket Kit...
  • Page 6 THERMOSTAT AND ZONING CONTROL OPTIONS NON---PROGRAMMABLE THERMOSTAT SELECTION For use with 1 speed Air Conditioner --- _F/_C, Auto Changeover TSTATCCNAC01 ---C TSTATCCNHP01 ---C* For use with 1 speed Air Conditioner --- _F/_C, Auto Changeover TSTATCCN2S01 ---C* For use with 2 speed Air Conditioner --- _F/_C, Auto Changeover * Model HP &...
  • Page 7 One pipe used or when a coil box other than a Carrier cased coil is used. It is runs inside the other allowing venting through the inner pipe and A.G.A.
  • Page 8 RECOVERY By adding moisture to winter-dry AIR CLEANER AND ZONING VENTILATOR air, a Carrier Humidifier can often improve comfort and keeps Cleans the air of smoke, dirt, and Available in programmable and Carrier‘s energy or heat recovery woodwork, wallpaper, and pain in many pollens commonly found.
  • Page 9: Physical Data

    PHYSICAL DATA UNIT SIZE DESCRIPTION 060--- 14 080--- 14 080--- 20 100--- 20 120--- 20 Direct--- Drive Motor Hp (ECM) Motor Full Load Amps 12.8 12.8 12.8 RPM (Nominal)—Speeds Variable 250 — 1300 Blower Wheel Diameter X Width (in.) 10 X 7 11 X 10 11 X 10 11 X 10...
  • Page 10: Operating Mode

    AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER) CFM Airflow External Static External Static Pressure (ESP) Operating Mode Unit Size Pressure Setting Range* 060--- 14 410{ Low Heat 0 ---0.50 560{ Medium Heat 0 ---0.50 1070{ 1065 1070 1070 1070 1070 1070 1070 1065 1045 1015 High Heat 0 ---1.0 1 ---1/2 ---Ton A/C Cooling...
  • Page 11: Condensate Trap

    B IN. DIA PVC VENT/EXHAUST C IN. DIA 1 /2 B IN. DIA PVC INTAKE/COMBUSTION AIR DIMENSIONS (IN / MM) KIT PART NO. KGAVT0501CVT 33--- 3/8 / 847.7 2 / 50.8 3--- 1/2 / 88.9 16--- 5/8 / 422.3 6--- 1/4 / 158.8 5--- 3/4 / 146.1 KGAVT0601CVT 38--- 7/8 / 987.4...
  • Page 13 DIMENSIONS (IN. / MM) FURNACE HOLE NO. PLENUM OPENING* FLOOR OPENING FURNACE IN DOWNFLOW CASING FOR WIDTH APPLICATION WIDTH ADJUSTMENT Furnace with or without 15--- 1/8 / 16--- 3/4 / 20--- 3/8 / 17--- 1/2 / 444.5 Cased Coil Assembly or Coil 19 / 482.6 384.2 425.5...
  • Page 14: Electrical Data

    ELECTRICAL DATA UNIT SIZE 060 ---14 080 ---14 080 ---20 100 ---20 120 ---20 UNIT VOLTS --- HERTZ --- PHASE 115 --- 60 --- 1 OPERATING VOLTAGE RANGE (Min --- Max)* 104 --- 127 MAXIMUM UNIT AMPS 8.96 8.96 14.06 14.06 14.06 MINIMUM WIRE SIZE...
  • Page 15 Maximum Allowable Pipe Length (Ft / M) Direct Vent (2 ---Pipe Only) NUMBER OF 90_ ELBOWS UNIT SIZE Termination Pipe Dia ALTITUDE (BTUH) Type (IN.)* 2 Pipe or 2--- In. 1--- 1/2 50 / 15.2 45 / 13.7 40 / 12.9 35 / 10.7 30 / 9.1 25 / 7.6...
  • Page 16 Maximum Allowable Pipe Length (Ft / M) (Continued) Direct Vent (2- -Pipe Only) NUMBER OF 90_ ELBOWS UNIT SIZE ALTITUDE Termination Pipe Dia (BTUH) Type (IN.)* 2 Pipe or 2--- In. 1--- 1/2 35 / 10.7 30 / 9.1 25 / 7.6 20 / 6.1 15 / 4.6 10 / 3.0...
  • Page 17: Installation

    INSTALLATION This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m), except 140 size furnaces are only approved for altitudes 0 - 7,000 ft. (0 - 2,135m). An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications. This furnace is for indoor installation in a building constructed on site.
  • Page 18 COMBUSTION AIR PIPE OUTDOOR UNIT VENT PIPE A/C COIL HUMIDIFIER GAS-FIRED ELECTRONIC WATER HEATER AIR CLEANER FRONT OF AIRFLOW FURNACE A06511 Upflow Application ELECTRONIC AIR CLEANER VENT COMBUSTION AIR (DIRECT VENT/ HUMIDIFIER 2 PIPE APPLICATION OUTDOOR UNIT A/C COIL AIRFLOW FRONT OF FURNACE A07799...
  • Page 19 COMBUSTION–AIR PIPE VENT PIPE DIRECT VENT/2-PIPE APPLICATION) OPTIONAL VENTILATED COMBUSTION AIR APPLICATION ELECTRONIC AIR CLEANER FRONT OF FURNACE FURNACE CONDENSATE DRAIN AIR CONDITIONING COIL REFRIGERATION PIPING AIRFLOW A07800 Attic --- Horizontal Application OPTIONAL VENTILATED COMBUSTION AIR INTAKE COMBUSTION– AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) VENT...
  • Page 20: Guide Specifications

    Refer to section of the product data identifying accessories and descriptions for specific features and available enhancements. Catalog No: 58MVC ---1PD Copyright 2007 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 08/07 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Table of Contents