Quick Links

®
Turn to the Expertg
Installation Instructions
Visit www.Carrier.com
NOTE:
Read
the
entire
instruction
manual
before
starting
the installation.
Please retain these instructions
with the furnace
after installation
for future reference.
NOTE:
This furnace can be installed as a (2-pipe)
direct
vent
or (1-pipe)
non-direct
vent condensing gas furnace.
ISO
9001:2000
11
Special
Venting
Requirements
for Installations
in Canada
Installation
in Canada
must conform
to the requirements
of CSA
B149
code.
Vent systems
must
be composed
of pipe, fittings,
cements,
and primers
listed
to ULC
$636.
The
special
vent
fittings
and
accessory
concentric
vent
termination
kits
and
accessory
external
drain trap have been certified
to ULC $636 for
use with
those IPEX
PVC
vent components
which
have
been
certified
to this standard.
In Canada,
the primer and cement must
be of the same manufacturer
as the vent system
- IPEX
System
636, PVC/CPVC
Primer,
Purple
Violet for Flue Gas Venting
and
IPEX
System
636(1)
TM
, PVC Cement
for Flue Gas Venting,
rated
Class IIA, 65 deg C. must be used with this venting
system
- do
not mix primers
and cements
from one manufacturer
with a vent
system
from a different
manufacturer.
Follow
the manufacturer's
instructions
in the use of primer and cement
and never use primer
or cement beyond
its expiration
date.
The safe operation,
as defined
by ULC $636,
of the vent system
is based
on following
these
installation
instructions,
the vent
system
manufacturer's
installation
instructions,
and proper
use of
primer and cement.
All fire stop and roof flashing
used with this
system
must be UL listed material.
Acceptability
under Canadian
standard
CSA
B149 is dependent
upon
full compliance
with all
installation
instructions.
Under
this standard,
it is recommended
that the vent system
be checked
once a year by qualified
service
personnel.
The
authority
having
jurisdiction
(gas
inspection
authority,
municipal
building
department,
fire department,
etc)
should
be
consulted
before
installation
to determine
the need
to obtain
a
permit.
Consignes sp_ciales pour l'installation de ventillation au Canada
L'installation faite au Canada doit se conformer aux exigences du
code CSA B149. Ce syst_me de ventillation doit se composer de
tuyaux, raccords, ciments et appr_ts conformes au ULC $636. La
tuyauterie de ventillation
des gaz, ses accessoires, le terminal
concentrique mural ainsi que l'ensemble du drain de condensat
ext_rieur ont _t_ certifies ULCS
636 pour l'application
des
composantes IPEX PVC qui sont certifi_es 5. ce standard.
Au
Canada l'appr_t et le ciment doivent _tre du m_me manufacturier
que le syst_me de ventillation
- IPEX Syst_me 636, Appr_t
PVC/CPVC. Mauve Violette pour conduit en _vacuation des gaz
et IPEX Syst_me 636(1)
TM,
ciment pour PVC pour conduit en
_vacuation des gaz, _valu_ CLASSE IIA, 65 deg. C. doit _tre
utilis_ avec ce syst_eme d'_vacuation
- ne pas m_langer l'appr_t
et le ciment d'un manufacturier avec le syst_me de ventillation
d'un
autre
manufacturier.
Bien
suivre
les indications
du
manufacturier lors de l'utilisation de l'appr_t et du ciment et ne
pas utiliser ceux-ci si la date d'expiration est atteinte.
L'op_ration s_curitaire, tel que d_finit par ULC $636, du syst_me
de ventilation est bass sur les instructions d'installation suivantes,
ainsi que l'usage appropri_ de l'appr_t et ciment. Tout arr_t feu et
solin de toit utilis_s avec ce syst_me doivent _tre des mat_riaux
list,s UL
L'acceptation
du standard Canadien CSA B419 est
directement reli_ 5. l'installation
conforme aux instructions ci-
haut
mentionn_es.
Le
standard
Canadien
recommande
1'
inspection par un personel qualifi_ et ce, une fois par annie.
Les autorit_es ayant juridiction (inspecteurs de gas, inspecteurs en
bfitiments,
d@artement
des incendies,
etc)
devraient
_tre
consult_es avant l'installation
afin de d_terminer si un permis est
requis.