Horizontalr Ight - Carrier Infinity ICS 58MVC 100 Series Installation Instructions Manual

Direct vent 4-way multipoise condensing gas furnace
Hide thumbs Also See for Infinity ICS 58MVC 100 Series:
Table of Contents

Advertisement

HORIZONTAL
R IGHT
(SUPPLY-AIR
DISCHARGE)
APPLICATIONS
A horizontal
right furnace
application
is where furnace
blower
is
located
to the left of combustion
and controls
section
of furnace,
and conditioned
air is discharged
to the right.
PROPERTY
DAMAGE
HAZARD
Failure
to
follow
this
caution
may
result
in property
damage.
Local
codes may require
a drain pan under
entire furnace
and condensate
trap when
a condensing
furnace
is used in
an attic application
or over a finished
ceiling.
NOTE:
In Canada, installations shall be in accordance with
current NSCNGPIC and/or local codes.
NOTE:
The auxiliary junction box (J-box)
MUST be relocated
to opposite side of furnace casing.
(See Fig. 14.) See Electrical
Connection section for J-box relocation.
Condensate
Trap Location
PLUG
COLLECTOR
BOX
COLLECTOR
BOX
DRAIN TUBE (BLUE)
TUBE (GREEN)
CAP
COLLECTOR
BOX TUBE (PINK)
AUXILIARY
"J" BOX
RELOCATED
HERE
COLLECTOR
BOX
[J _
CONDENSATE
DRAIN TUBE (BLUE &
t]_]3
TRAP
WHITE STRIPED)
INDUCER
HOUSING
(MOLDED)
DRAIN
TUBE (VIOLET)
COLLECTOR
BOX
EXTENSION
TUBE
Fig. 14 - Horizontal
Right 1hbe Configuration
A07279
The condensate trap must be removed from the factory-installed
blower
shelf location
and relocated
in selected
application
location as shown in Fig. 2 or 14.
To relocate condensate
trap from the blower shelf to desired
location, perform the following:
1. Remove three tubes connected to condensate trap.
2. Remove trap from blower shelf by gently pushing tabs in-
ward and rotating trap.
CARBON
MONOXIDE
POISONING
HAZARD
Failure to follow this warning
could result in personal
injury or death.
Casing hole filler cap must be installed in blower shelf hole
when condensate trap is relocated to prevent
combustion
products being drawn in from appliances in the equipment
room.
3. Install casing hole filler cap (factory-supplied
in loose
parts bag) into blower shelf hole where trap was removed.
4. Install condensate trap into right-hand side casing hole by
inserting tube connection tabs through casing hole and ro-
tating until tabs snap into locking position.
5. Fill unused condensate trap casing holes with plastic filler
caps (factory-supplied
in loose parts bag).
UPFLOW OR DOWNFLOW
MIN I/4" (7[l_Lm _
TO 1/2" (13mm)
MAX
HORIZONTAL
A02146
Fig. 15 - Proper
Condensate
Drainage
Condensate
Trap Tubing
NOTE:
See Fig. 14 or tube routing
label on main furnace
door
to check for proper
connections.
1. Collector
Box Drain Tube
a. Remove
factory-installed
plug from LOWER
collector
box drain tube (blue and white striped
label).
b. Install
removed
clamp
and plug into UPPER
collector
box drain tube (blue label) which was previously
connec-
ted to condensate
trap.
c. Connect
LOWER
collector
box
drain
tube
(blue
and
white striped
label) to condensate
trap.
Tube does not
need to be cut.
d. Clamp tube to prevent
any condensate
leakage.
2. Inducer
Housing
Drain Tube
(a.)Remove
factory-installed
cap and clamp
from
LOWER
inducer
housing
drain connection.
(b.)Remove
and discard
UPPER
(molded)
inducer
housing
drain
tube which
was previously
con-
nected to condensate
trap.
(c.)Install
cap and clamp on UPPER
inducer
hous-
ing drain
connection
where
molded
drain tube
was removed.
(d.)Use
inducer
housing
drain extension
tube (violet
label and factory-supplied
in loose parts bag) to
connect
LOWER
inducer
housing
drain connec-
tion to condensate
trap.
(e.)Deternfine
appropriate
length,
cut, and connect
tube to condensate
trap.
(f.)Clamp
tube to prevent
any condensate
leakage.
3. Relief Port Tube
Refer to Pressure
Switch
Tubing
section for recommenda-
tions and procedures.
Condenste
Trap
Field Drain
Attachment
Refer
to Condensate
Drain
section
for recommendations
and
procedures.
Pressure
Switch
1hbing
One collector
box pressure
tube (pink label) is factory
connected
to the
pressure
switch
for
use
when
furnace
is installed
in
UPFLOW
or HORIZONTAL
LEFT
applications.
This
tube
MUST
be disconnected
and used for the condensate
trap relief
port tube,
The other
collector
box
pressure
tube (green
label)
which
was factory
connected
to the condensate
trap relief port
connection
MUST
be
connect
to
the
pressure
switch
in
DOWNFLOW
or HORIZONTAL
RIGHT
applications,
15