Carrier Infinity ICS 58MVC 100 Series Installation Instructions Manual page 12

Direct vent 4-way multipoise condensing gas furnace
Hide thumbs Also See for Infinity ICS 58MVC 100 Series:
Table of Contents

Advertisement

AUXILIARY
"J" BOX
PLUG
CAP
COLLECTOR BOX
DRAIN TUBE (BLUE &
WHITE STRIPED)
CONDENSATE
TRAP
COLLECTOR BOX
TUBE
EXTENSION
COLLECTOR BOX
EXTENSION
DRAIN TUBE
DRAIN TUBE
COUPLING
COLLECTOR BOX
TUBE (GREEN)
INDUCER HOUSING
(MOLDED)
DRAIN
TUBE (VIOLET)
COLLECTOR BOX
DRAIN TUBE (BLUE)
COLLECTOR BOX
TUBE (PINK)
Fig. 11 - Horizontal
Left Tube Configuration
A07278
b. Remove and discard UPPER (molded) inducer housing
drain tube which was previously connected to condensate
trap.
c. Install cap and clamp on UPPER inducer housing drain
connection where molded drain tube was removed.
d. Use inducer housing drain tube (violet label and factory-
supplied in loose parts bag) to connect LOWER inducer
housing drain connection to the condensate trap,
e. Connect inducer housing drain connection to condensate
trap.
(1.) Condensate Trap Located on Left Side of Casing
(a.)Determine appropriate length and cut.
(b.)connect tube to condensate trap.
(c.)Clamp tube to prevent any condensate leakage.
(2.) Condensate Trap Located on Right Side of Casing
(a.)Route inducer housing drain tube (violet label)
directly from inducer housing
to condensate
trap.
(b.)Determine appropriate length and cut.
(c.)Connect tube to condensate trap.
(d.)Clamp tube to prevent any condensate leakage,
3. Relief Port Tube
Refer to Pressure Switch Tubing section for connection
procedure,
Condensate
Trap Field Drain Attachment
Refer to Condensate
Drain section for recommendations
and
procedures.
Pressure Switch Tubing
One collector box pressure tube (pink label) is factory connected
to the pressure switch for use when furnace is installed in
UPFLOW
or HORIZONTAL
LEFT applications.
The tube
MUST
be disconnected
and used or the condensate
trap relief
port tube,
The other
collector
box
pressure
tube (green
label)
which
was factory
connected
to the condensate
trap relief port
connection
MUST
be
connected
to
the
pressure
switch
in
DOWNFLOW
or HORIZONTAL
RIGHT
applications.
NOTE:
See Fig. 9 or 10 or tube routing
label on man furnace
door to check for proper
connections.
Relocate
tubes as described
below.
1. Disconnect
collector
box
pressure
tube
(pink
label)
at-
tached to pressure
switch.
2. Extend
collector
box
pressure
tube
(green
label)
which
was previously
connected
to condensate
trap relief port
connection
by splicing
to small diameter
tube (factory-
supplied
in loose parts bag).
3. Connect
collector
box pressure
tube (green
label) to pres-
sure switch connection
labeled
COLLECTOR
BOX.
4. Extend
collector
box pressure
tube (pink label) which was
previously
connected
to pressure
switch
by splicing
to re-
maining
small
diameter
tube
(factory-supplied
in loose
parts bag).
5. Route
this extended
tube (pink
label) to condensate
trap
relief port connection.
6. Determine
appropriate
length,
cut, and connect
tube.
7. Clamp tube to relief port connection.
Condensate
Trap Freeze Protection
Refer
to
Condensate
Drain
Protection
section
for
recommendations
and procedures.
HORIZONTAL
LEFT
(SUPPLY-AIR
DISCHARGE)
APPLICATIONS
A horizontal
left furnace
application
is where
furnace
blower
is
located to the right of combustion
and controls
section
of furnace,
and conditioned
air is discharged
to the left,
12