Carrier Infinity ICS 58MVC 100 Series Installation Instructions Manual page 26

Direct vent 4-way multipoise condensing gas furnace
Hide thumbs Also See for Infinity ICS 58MVC 100 Series:
Table of Contents

Advertisement

B
115-V f
SINGLE
PHASE
....
FIELD 24-V WIRING
....
FIELD 115-, 208/280-, 460-V WIRING
--
FACTORY 24-V WIRING
FACTORY 115-, 208/230-, 460-V WIRING
115-V
AUXILIARY
FIELD-SUPPLIED
J-BOX
DISCONNECT
SWITCH
FURNACE
CONTROL
CENTER
NOTE 5 ,
_
_
I THERMOSTAT
WIRE
_
'
I
I
I
I
t
DISCONNECT
I
I
J
I
..........................
THREE-W,RE----- ' '
'11
HEATING
_L_---I
I
I
ONLY
_'-
--
I
I
, 11
I
I
}N;NN{i
{
@ NOTE',
3
*
f_
t
r-J--A--e----eh
o-4l-e.==_o===
;_ SINGLE
f-J
', ',
{ }
_
....
4_______L==J
PHASE
(_
....
NOTE1
J Ii [-_--O---_ND
r-_
-]------_NDI
/ 1 .............
.......
I _,
CONDENSING
L_Y
\
UNIT
24-V
TWO Wl RE
TERMINAL
BLOCK
NOTES:
1. Connect Y or Y/Y2 terminal as shown for proper cooling operation.
2. Proper polarity must be maintained for 115-v wiring.
8. Use W2 with 2-stage thermostat when zoning.
4. If any of the original wire, as supplied, must be replaced, use
same type or equivalent wire.
5. Some thermostats require a "C" terminal connection as shown.
208/230- OR
460-V
THREE PHASE
Fig. 29 - Heating
and Cooling
Application
Wiring
Diagram
A98325
Table 4 - Electrical
Data
UNIT SIZE
VOLTS-
HERTZ-
PHASE
OPERATING
VOYAGE
RANGE
MAXIMUM
UNIT
AMPS
Maximum*
127
127
127
127
127
Minimum*
104
104
104
104
104
MINIMUM
WIRE SIZE
060-14/042060
115-60-1
8.96
14
080-14/042080
115-60-1
8.96
14
080-20/060080
115-60-1
14.06
12
100-20/060100
115-60-1
14.06
12
120-20/060120
115-60-1
14.06
12
MAXIMUM
WIRE
LENGTH
FT (M)_
30 (9.1)
60 (9.1)
31 (9.4)
31 (9.4)
31 (9.4)
MAXIMUM
FUSE
OR CKT
BKR
AMPS**
15
15
2O
2O
2O
* Permissible limits of voltage
range at which unit will operate satisfactorily.
1- Unit ampacity
= 125 percent of largest operating
component's
full load amps plus 100 percent of all other potential operating
components'
(EAC,
humidifier,
etc.) full load amps.
$ Length shown is as measured
1 way along wire path between
unit and service panel for maximum
2 percent voltage drop.
** Time-delay
type is recommended.
ELECTRICAL
SHOCK
AND FIRE HAZARD
Failure to follow this warning
could result in electrical
shock, fire, or death.
The cabinet MUST have an uninterrupted
or unbroken
ground
according
to NEC ANSI/NFPA
70-2008
and
Canadian Electrical Code CSA C22.1 or local codes to
nfininfize personal injury if an electrical fault should occur.
This may consist of electrical wire or conduit approved for
electrical ground when installed in accordance with existing
electrical codes. Do not use gas piping as an electrical
ground.
ELECTRIC
DISCONNECT
SWITCH
Q
Fig. 30 - Disconnect
Switch
and Furnace
A93033
Install power entry hole filler plugs (factory-supplied
in loose
parts bag) in unused power entry holes. (See Fig. 31.)
26