Carrier Infinity ICS 58MVC 100 Series Installation Instructions Manual page 54

Direct vent 4-way multipoise condensing gas furnace
Hide thumbs Also See for Infinity ICS 58MVC 100 Series:
Table of Contents

Advertisement

NOTE:
Reference
Fig. 52-59:
1. Heat pump
MUST
have
a high pressure
switch
for dual
fuel applications.
2. Refer
to outdoor
equipment
Installation
Instructions
for
additional
information
and setup procedure.
3. Select the "ZONE"
position
on the two-speed
heat pump
control.
4. Outdoor
Air Temperature
Sensor
must
be attached
in all
dual fuel applications.
5. Dip switch No.l
on Thermidistat
should be set in OFF po-
sition
for air conditioner
installations.
This is factory
de-
fault.
6. Dip switch No. 1 on Thermidistat
should be set in ON po-
sition for heat pump installations.
7. Dip switch
No. 2 on Thermidistat
should
be set in OFF
position
for single-speed
compressor
operation.
This
is
factory default.
8. Dip switch No. 2 on Thermidistat
should be set in ON po-
sition for two-speed
compressor
operation.
9. Configuration
Option
No. 10 "Dual Fuel Selection"
must
be turned ON in all dual fuel applications.
10. NO connection
should
be made to the furnace
HUM
ter-
minal when using a Thermidistat.
11. Optional
connection.
If wire is connected
to W2 on fur-
nace control board, either dip switch SWI-2
or SW4-2
on
furnace
control
should
be set in ON position
to allow
Thernaidistat/Thernmstat
to control
furnace
at 2 stages
Low/High
or Medium/High.
12. Optional
connection.
If wire is connected,
ACRDJ
jumper
on furnace
control
should be removed
to allow Thermidis-
tat/Thermostat
to control
outdoor
unit staging.
13. Furnace
nmst control its own staging operation
via furnace
control
algorithm.
This is factory default.
14. The RVS Sensing
terminal
"L" should
not be connected.
This is internally
used to sense defrost
operation.
15. DO NOT
SELECT
the
"FURNACE
INTERFACE"
or
"BALANCE
POINT"
option on the two-speed
heat pump
control
board. This is controlled
internally
by the Thermi-
distat/Dual
Fuel Thermostat.
16. Dip switch
D on Dual
Fuel
Thermostat
should
be set in
OFF position
for single-speed
compressor
operation.
This
is factory default.
17. Dip switch
D on Dual
Fuel
Thermostat
should
be set in
ON position
for two-speed
compressor
operation.
Step
4 --
Adjustments
Set Gas Input Rate
Furnace
gas
input
rate
on rating
plate
is for
installations
at
altitudes
up to 2000 ft. (609.6M).
In the
USA.,
the
input
rating
for
altitudes
above
2000
ft.
(609.6M)
nmst
be
reduced
by
2 percent
for each
1000
ft.
(304.8M)
above sea level.
In Canada,
the input
rating
must
be derated
by 5 percent
for
altitudes
of 2000 ft. (609.6M)
to 4500 ft. (1371.6M)
above
sea
level.
Adjust manifold
pressure
to obtain input rate.
Furnace
input
rate must
be within
+2 percent
of input
rate on
furnace
rating plate.
1. Determine
natural
gas orifice
size and manifold
pressure
for correct input.
a. Obtain average heat value (at installed altitude) from local
gas supplier.
b. Obtain
average specific
gravity from local gas supplier.
c. Verify furnace model. Table 10 can only be used for mod-
el 58MVC Furnaces.
d. Find installation altitude in Table 10.
NOTE:
For Canadian altitudes of 2000 to 4500 ft. (609.6 to
1371.6M), use USA. altitudes of 2001 to 3000 ft. (609.6 to
914.4M) in Table 10.
e. Find closest natural gas heat value and specific gravity
in Table 10.
f. Follow heat value and specific gravity lines to point of
intersection to find orifice size and low-, medium-, and
high-heat manifold pressure settings for proper opera-
tion.
EXAMPLE:
0 - 2000 ft. (0 - 609.6M)
altitude
Heating
value = 1050 Btu/cu ft.
Specific
gravity = 0.62
Therefore:
Orifice No. 45
Manifold
pressure:
3.8-in.
wc for high heat 1.6-in.
wc for medium
heat 0.6-in.
wc for low heat
* Furnace
is shipped
with No. 45 orifices. In this example,
all main
burner orifices are the correct size and do not need to be changed
to
obtain proper
input rate.
g. Check and verify burner
orifice size in furnace.
NEVER
ASSUME
ORIFICE
SIZE;
ALWAYS
CHECK
AND
VERIFY.
2. Adjust manifold
pressure
to obtain input rate.
HIGH-HEAT
ON/OFF
(UNDER
CAP)
INLET
_i
PRE_SAU_E
BURNER
ENCLOSURE
REFERENCE
TAP
MEDIUM-HEAT
ADJUSTMENT
(UNDERCAP)
LOW-HEAT
ADJUSTMENT
(UNDERCAP)
MANIFOLD J
PRESSURE
TAP
Fig. 60 - Redundant
Automatic
Gas Valve
A07280
a. Remove
burner
enclosure
front.
NOTE:
Manifold
pressure
MUST
always be measured
with the
burner box cover REMOVED.
b. Remove
regulator
seal caps
that
conceal
adjustment
screws for medium-
and high-heat
gas valve regulators.
(See Fig. 60.)
c. Move setup switch SW4-2
on control center to ON posi-
tion. (See Fig. 33.) This keeps furnace locked in medium-
heat operation.
54