Carrier Infinity ICS 58MVC 100 Series Installation Instructions Manual page 4

Direct vent 4-way multipoise condensing gas furnace
Hide thumbs Also See for Infinity ICS 58MVC 100 Series:
Table of Contents

Advertisement

g
1
664 ram)
2 IN (51 mm)
COMBUSTION
!_lN(13mm)
GAS
CONN
2IN
VENTCONN
]_INDIA(13mm)
(684
ram)
TRAP
LOCATION
(DOWNFLOW
&
HORIZONTAL
LEFT)
;a IN D]A (22ram)
--POWER
CONN
ACCESSORY
POWER
ENTRY
DRAIN
TRAP
]
LOCATION
(ALTERNATE
UPFLOW)
9_s"
17 _16"
TYP
(439
(240 ram)
(21 ram)
TYP
(829 ram)
©
AIRFLOW
A_
(14 ram)
D--
'l:,r,,
"{P
OUTLET
CONDENSATE
DRAIN
(DOWNFLOW
&
HORIZONTAL
RIGHT)
"_
OR ALTERNATE
!_z IN
D]A GAS
CONN
1
_NLET
_E_
DRAIN
LOCATION
11'!6"_
_
1'16"
(UPFLOW)
(17 ram)
(17 ram)
26 i¢,,
(724 mm)
_26
%6"
(664 mm)
2614"
(667
mm)
22 5i_" (567
mm)_
_19"(463
ram) _
_!3fl6"
(21 ram)
I /
COMBUSTION
AIR OONN
b6"|
GAS
OONN
........ /
17 . .....
T_4 E R M O S+_,]r_'T
Ry
/
3O 1<
/+-.
2
N _/T,r,l_5
39 7S"
(.........
)
f_
_'_"-
_/ENTSONN
(.........
)
SIDE
INLET
,
1
b
<1
..........
DRAIN
LOCATION
/
_
22 11"TYP
------'_'_1
_g_6"
(11 ram)
(UPFLOW)
(a65 ram)
..............
J
--------_OT_;_1r'47----I I
......
"1 ........
)
FOR
HORIZONTAL
HANGING
(614 ram)
NOTES:
1.
Minimum
return-air
openings
at furnace,
based
on metal
duct.
If flex duct
is used,
see flex duct
manufactureris
recommendations
for equivalent
diameters.
2.
Minimum
return-air
opening
at furnace:
a. For 800
OFM
16-in.
(408mm)
round
or 141A (388 mm)x
12-in.
(305 mm) rectangle
b. For !200
CFM
20-in.
(508mm)
round
or 141# (368mm)x
197Mn.
(495mm).rectangle
c. For !600
CFM
22-in.
(558mm)
round
or 141# (368mm)x
231/4-in,(591mm)
[ectangle
d. For aidlow
requirements
above
1800 CFM,
see Air Delivery
table
in Product
Data
literature
for specific
use of single
side
inlets. The use
of both
side
inlets,
a
combination
of 1 side
and the bottom,
or the
bottom
only will
ensure
adequate
return
air openings
for airflow
requirements
above
1800
CFM.
A05124
Dimensions
(In. / mm)
UNIT
SIZE
A
D
E
080-14
/ 042080
17-1/2
/ 445
15-7/8
/ 403
16 / 406
080-14
/ 042080
21 / 533
19-3/8
/ 492
19-1/2
/ 495
080-20
/ 080080
21 / 533
19-3/8
/ 492
19-1/2
/ 495
100-20
/ 080100
21 / 533
19-3/8
/ 492
19-1/2
/ 495
120-20
/ 080120
24-1/2
/ 822
22-7/8
/ 581
23 / 584
Fig. 2 - Dimensional
Drawing
In Canada,
refer to the current
editions
of the National
Standards
of Canada
CAN/CSA-BI49.1
and .2 Natural
Gas and Propane
Installation
Codes,
and Canadian
Electrical
Code CSA C22.1
Recognize
safety information.
This is the safety-alert
symbol/_.
When
you
see this symbol
on the unit
and in instructions
or
manuals,
be alert to the potential
for personal
iniury.
Understand
the
signal
words
DANGER,
WARNING,
and
CAUTION.
These words
are used with the safety-alert
symbol.
DANGER
identifies
the most serious hazards
which will result in
severe
personal
iniury
or death.
WARNING
signifies
hazards
which
could
result
in personal
iniury
or death.
CAUTION
is
used
to identify
unsafe
practices
which
may
result
in nfinor
personal
iniury or product
and property
damage.
NOTE
is used
to
highlight
suggestions
which
will
result
in
enhanced
installation,
reliability,
or operation.
ENVIRONMENTAL
HAZARD
Failure
to follow
this caution
may result
in environmental
polution.
Remove
and recycle
all components
or materials
(i.e., oil,
refrigerant,
control boards,
etc.) before unit final disposal.
The 58MVC
Condensing
Gas-Fired
Furnaces
are CSA (formerly
AGA
and CGA)
design-certified
for natural
and propane
gases
(see furnace
rating
plate)
and for installation
in alcoves,
attics,
basements, closets, utility rooms, crawlspaces, and garages.
The
furnace is factory-shipped
for use with natural gas. A CSA listed
gas conversion kit is required to convert furnace for use with
propane gas.
See Fig. 3 for required clearances to combustibles.
Maintain a 1-in. (25 ram) clearance from combustible materials
to supply air ductwork for a distance of 36 inches (914 ram)
horizontally from the furnace.
See NFPA 90B or local code for
further requirements.
These furnaces SHALL NOT be installed directly on carpeting,
tile, or any other combustible material other than wood flooring.
These furnaces are suitable for installation in a structure built on
site or a manufactured
building completed
at final site. The
design of this furnace line is NOT CSA design-certified
for
installation in recreation vehicles, manufactured (mobile) homes
or outdoors.
This furnace is designed
for continuous
return-air
minimum
temperature of 60 °F (16 ° C) db or internfittent operation down to
55°F
(13°C)
db such as when used with a night setback
thermostat. Return-air temperature nmst not exceed 80 ° F (27 ° C)
db. Failure to follow these return air linfits may affect reliability
of heat exchangers, motors and controls. (See Fig. 4.)
These furnaces are shipped with the drain and pressure tubes
connected for UPFLOW applications.
Minor modifications are
required when used in DOWNFLOW,
HORIZONTAL
RIGHT,
or HORIZONTAL
LEFT
(supply-air
discharge
direction)
applications as shown in Fig. 1.
See details in Applications
section.