Email Options; Send Test Report; Devices And Optional Modules; Device Status - Bosch Solution 144 User Manual

Hide thumbs Also See for Solution 144:
Table of Contents

Advertisement

Comms > MyAlarm >

Email Options

This menu allows the master user to select which event
types will be reported using the email reporting function.
By default the first 4 options are set to report via email.
Follow the procedure below to configure the required
options.
Option
Description
1
Open Close Reports
2
Zones Reports
3
System Reports
4
Access Reports
5
Reserved
6
Reserved
7
Reserved
8
Reserved
Table 7: Email Options
1. Enter your Master PIN + [MENU].
2. Enter [5] + [5] + [9] + [OK].
The keypad will display the list of current options.
Options with a preceeding tick mark are selected.
Open Close
 Zones
 System
Press

3. Use the [] and [] keys to highlight the feature that
you want to program, then use the [ON] and [OFF]
keys to turn on and off the features as required.
4. When all email options are programmed, press [OK]
to save and exit, or press [MENU] to exit without
saving.
Comms > Periodic Test >

Send Test Report

This menu allows you to test the reporting functions of the
control panel by manually sending a 'Test' report to the
receiving party (i.e. security company monitoring station,
mobile telephone etc).
1. Enter [MENU] + [5] + [9] + [0].
The keypad will prompt that it is in the process of
sending a test report.
Comms testing in
progress. Please wait..
Press OK or MENU
If the test is successful, the keypad will prompt:
Bosch Security Systems 04/12 BLCC600U
MENU 5-5-9
Default
Send Reports
Send Reports
Send Reports
Send Reports
OK ON OFF MENU
MENU 5-9-0
Communications Test
Successful
Press OK or MENU
If the test is NOT successful, the keypad will prompt:
Test Report Failed..
Please Call for service
Press OK or MENU
2. Press [OK] or [MENU] to exit.

Devices and Optional Modules

Programming options in this section relate to the keypads
and other devices which may be connected to your alarm
system. Your installer will advise you on the exact makeup
and configuration of your system.
Devices > Commands >

Device Status

This option provides a listing of all of the devices and
modules connected to your system. Using this option it
is poosible to view the voltage, temperature and other
information about each of the modules.
Enter programming mode (PIN + MENU) then,
1. Press [MENU] + [6] + [0] + [0].
Kp1 Keypad 1 Name
Kp2 Keypad 2 Name
Ox1 Output Exp 1
Press

2. Use the [] and [] keys to select the device that you
want to view, then press [OK] to select.
3. The display will show each parameter for the device
one at a time on the third line of the screen.
Keypad Name Kp1
Graphic + Prox V2.05
Voltage = 13.87
Press OK or MENU
4. Press [OK] or [MENU] to exit.
Devices > Commands >

Volume

This menu allows you to adjust the volume of the keypad's
buzzer. Each keypad will need to have their volume
adjusted separately.
Enter programming mode (PIN + MENU) then,
1. Press [MENU] + [6] + [0] + [7].
The keypad will display: