6 The IOM2 interface and CODEC are tested. If a fault occurs, the self test
terminates and the message BAD IOM2/CODEC is displayed.
7 If all the previous tests have been successful then all dot segments of the
dot matrix display are illuminated, all the LEDs are lit and a short beep is
emitted.
8 The user now lifts the handset and the display is cleared.
The user presses keys in this sequence: Loudspeaker Mute Program LNR Hold
1 2 3 4 5 6 7 8 9 * 0 # Shift M1 M2 M3 M4. Each key press is displayed.
9 After each key is detected in the sequence a short beep is emitted. If an
incorrect key is pressed then an error tone is emitted. A pause of more than
5 seconds between keys results in the same error tone being emitted. On
completion, all of the LEDs are extinguished.
10 The user must then replace the handset. At this point the ringer is sounded
with continuous ring at medium volume and using bi-tone ring until the user
goes off-hook.
11 Lifting the handset terminates the self test mode and lets the watch-dog
expire to reset the terminal. The terminal generates an outgoing call request
in response to the off-hook condition.
Loudspeaker
Mute
Er goLi ne
ABC
DEF
2
3
1
GHI
JKL
M N O
6
4
5
TUV
PQRS
W XYZ
8
9
7
0
F
5.2 D320
IGURE
KEYS
ErgoLine D310/320
Customer Engineer Manual
Hold
LNR
Program
Shift
M4
M3
Memory Keys
M2
M1
Page 5-13