Pnt1; S Interface; Interface - Philips ErgoLine D330 Manual

Table of Contents

Advertisement

ErgoLine D310/320
Customer Engineer Manual
PNT1 (for use with 4-wire interface)
The ErgoLine D310 and D320 can be connected to the Switch via a Private
Network Termination (PNT1).
The EAZ of the ErgoLine D310/D320 should be adjusted as if the terminal was
connected to an S0-bus.
The PNT1 is equipped with two eight way modular sockets for the connection of
two S
ErgoLine terminals. On both jacks the corresponding pins 3, 4, 5 and 6 are
0
interconnected: 3 to 3, 4 to 4, etc.
Pin Outs
Pin
Signal
1
n/c
2
n/c
3
Receive +
(power +)
4
Transmit +
(power -)
5
Transmit -
(power -)
6
Receive -
(power +)
7
n/c
8
n/c
S

Interface

0
This interface is the standard SOPHO iS3000 S
To identify the terminal at the S
Ziffer (EAZ) below.
U
interface
PN
The ErgoLine D310 and D320 can be connected to the switch via the DLX-U U
interface. This is a two wire digital interface which uses ping-pong signalling. (Do
not mistake this interface with the echo-cancelling proprietary Philips U-interface).
This interface is capable of supporting the connection of one terminal only.
Normally, the DLX-U U
terminals.
The D310 and D320 terminal may also replace a D340 terminal that is connected
to a 2B+D mode projected DLX-U board. Remember that 2B+D mode is required
for the D340 when it uses both the voice and the data port. When a D310 or D320
terminal is connected to the DLX-U board in 2B+D mode only one B-channel is
used per port, while the other B-channel is left unused.
Page 5-6
-bus see the section entitled Endgerät Auswahl
0
board should be projected in 1B mode for D310/D320
PN
interface.
0
PN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ergoline d310Ergoline d320Ergoline d340

Table of Contents