Figure 138 Enabling Tr-069; Table 105 Tr-069 Commands - ZyXEL Communications P-660HWP-D1 User Manual

802.11g homeplug av adsl2+ security gateway
Hide thumbs Also See for P-660HWP-D1:
Table of Contents

Advertisement

Follow the procedure below to configure your P-660HWP-D1 to be managed by CNM
Access. See the Command Interpreter appendix for information on the command structure and
how to access the CLI (Command Line Interface) on the P-660HWP-D1.
In this example a.b.c.d is the IP address of CNM Access. You must change
this value to reflect your actual management server IP address or domain
name. See

Figure 138 Enabling TR-069

ras> wan tr069 load
ras> wan tr069 acsUrl a.b.c.d
Auto-Configuration Server URL: http://a.b.c.d
ras> wan tr069 periodicEnable 1
ras> wan tr069 informInterval 2400
TR069 Informinterval 2400
ras> wan tr069 active 1
ras> wan tr069 save
The following table gives a description of TR-069 commands.

Table 105 TR-069 Commands

COMMAND OR
ROOT
SUBDIRECTO
COMMAND
RY
wan
tr069
load
active [0:no/
1:yes]
acsUrl <URL>
username
[maxlength:15]
password
[maxlength:15]
periodicEnable
[0:Disable/
1:Enable]
informInterval
[sec]
save
P-660HWP-D1 User's Guide
Table 105 on page 241
DESCRIPTION
All TR-069 related commands must be preceded by wan tr069.
Start configuring TR-069 on your P-660HWP-D1.
Enable/disable TR-069 operation.
Set the IP address or domain name of CNM Access.
Username used to authenticate the device when making a
connection to CNM Access. This username is set up on the server
and must be provided by the CNM Access administrator.
Password used to authenticate the device when making a
connection to CNM Access. This password is set up on the server
and must be provided by the CNM Access administrator.
Whether or not the device must periodically send information to
CNM Access. It is recommended to set this value to 1 in order for
the P-660HWP-D1 to send information to CNM Access.
The duration in seconds of the interval for which the device MUST
attempt to connect with CNM Access to send information and
check for configuration updates. Enter a value between 30 and
2147483647 seconds.
Save the TR-069 settings to your P-660HWP-D1.
Chapter 17 Remote Management Configuration
for detailed descriptions of the commands.
241