Download Print this page

Stanley 83KM-93KM Installation Instructions Manual page 8

Idh max cylindrical lock

Advertisement

Installation Instructions for 83KM/93KM–85KM/95KM IDH Max Cylindrical Locks
Hinge mortise
Field harness &
RH/RHRB reader
wire hole
Field wire
harness
Fire plate with PCB
Figure 7 Pulling the field wire harness through the
door
8
Inside of door
BEST ACCESS SYSTEMS
a Product Group of Stanley Security Solutions, Inc
Preparing the door and door jamb
7
Pull field wire harness through door
1 Route the field wire harness (connected to the PCB)
through the wire routing hole in the fire plate and into
the hole drilled through the door to the hinge mortise.
2 From the latch edge of the door, fish the field wire
harness through the door to the hinge mortise.
3 Make sure there are 3 to 4 inches of slack in the field
wire harness to allow access to the control electronics
circuit board in the inside trim.
.

Advertisement

loading

This manual is also suitable for:

85km-95km