Installing the panel interface module
25
Connect field wiring from wire transfer
hinge to panel interface module
1 Connect the two communication field wires (run from
the wire transfer hinge) to the COM+ and COM–
terminals on the panel interface circuit board.
Note: The field wire harness leads, connected to the
door side of the wire transfer hinge, are described in
the table below.
Wire
Color
Ground
Black
12 VDC
Red
Com+
Orange
Com–
Green
2 If you are providing power to the lock through the
panel interface module, connect the two power field
wires (run from the wire transfer hinge) to the 12V and
GND terminals on the panel interface circuit board.
Note: JP2 and JP3, shown in Figure 22a, are used for
manufacturing purposes only.
3 Connect the RS-485 shield wire to one of the GND
terminals on J1.
26
Connect panel interface module to
access control panel/reader interface
With power removed from the panel interface circuit
board and the access control panel/reader interface,
connect the wiring between the panel interface circuit
board and the access control panel/reader interface.
Refer to the table below.
Installation Instructions for 83KM/93KM–85KM/95KM IDH Max Cylindrical Locks
Installation Instructions for 83KM/93KM–85KM/95KM IDH Max Cylindrical Locks
3
1
Figure 22a Panel interface circuit board
Figure 22b Connecting field wiring from the wire
Figure 22c Connecting to the access control panel/
BEST ACCESS SYSTEMS
a Product Group of Stanley Security Solutions, Inc
IDH Panel Interface
P2
P3
1
8
TPR
DLS
RQE
STK
Connect to wire
transfer hinge.
transfer hinge
3
PR
DLS
RQE
Connect to access control panel/reader interface.
reader interface
OFF
ON
1
SW1
8
1
D0
D1 RED RN BPR
ND
NC
NC CP
1
S K
2
9
19

Advertisement

loading

This manual is also suitable for:

85km-95km