Error and information messages

8

8.1 Error messages

Error
code
Sewing motor
1051
1052
1053
1055
1056
1058
1302
1342
1344
Stepper motors
2101
2102
2152
Operating instructions 906 - Version 00.0 - 05/2014
Error and information messages
Description
Sewing motor timeout
• Cable to sewing motor reference
switch defective
• Reference switch defective
• Upper part does not move freely or
has excessive belt tension
Excessive sewing motor current
• Sewing motor cable defective
• Sewing motor defective
• Controller defective
Sewing motor mains voltage too high Check the mains voltage
Sewing motor overload
• Sewing motor blocked/not moving
freely
• Sewing motor defective
• Controller defective
Sewing motor overtemperature
• Sewing motor not moving freely
• Sewing motor defective
• Controller defective
Sewing motor speed
• Sewing motor defective
Sewing motor error
Controller not receiving pulses from
pulse encoder in motor
Sewing motor error
Internal error
X-axis stepper motor referencing time-
out
• Faulty reference switch setting
• Cable to reference switch defective
• Reference switch defective
X-axis stepper motor current error
• Stepper motor blocked
• Encoder cable not connected or
defective
• Encoder defective
X-axis stepper motor overcurrent
Remedy
• Replace the cable
• Replace the reference switch
• Check the freedom of movement
and belt tension of the upper part
• Replace the sewing motor cable
• Replace the sewing motor
• Replace the controller
• Remove the blockage/cause of lack
of freedom of movement
• Check the sewing motor
• Check the controller
• Remove the cause of the lack of
freedom of motion
• Replace the sewing motor
• Replace the controller
• Replace the sewing motor
• Check the cable from the pulse
encoder in the motor to the control-
ler
• Switch the machine off and on again
• Software update
• Adjust reference switch
• Replace the cable
• Check reference switch
• Remove the blockage
• Check/replace the encoder cable
• Replace the stepper motor
• Replace the stepper motor
• Replace the controller
119