10.2 Dismantling the automatic stacker

The dismantling of the automatic stacker is optional. However, it could be
necessary to dismantle it for transport or space-saving storage.
Figure 81: Dismantling the automatic stacker
(1) - Setscrews
(2) - Threaded screws
(3) - Cover plate
(4) - Support pipe
1. Switch off the machine at the main switch.
2. Release quick coupling of the main compressed air supply.
3. Disconnect the compressed air hose on the valve block from the pneu-
4. Disconnect plugs of the valve control lines (6).
5. Remove the equipotential bonding (7):
128
WARNING
Risk of injury.
The automatic stacker is heavy and has bulky
dimensions.
Carry out the dismantling with two people in order
to avoid back injuries or crushing injuries if the
machine falls down.
matic connection (5).
• When disconnecting, simultaneously release the lock.
• Loosen hexagonal socket screw (screwdriver width 4 mm)
• Remove the equipotential bonding line.
Decommissioning
(5) - Pneumatic supply
(6) - Plug for valve control lines
(7) - Equipotential bonding
Operating instructions 906 - Version 00.0 - 05/2014