POST Error Code
10450, 10451, 10490,
10491, 10492, 10499Read/write error
10452 Seek test error
10453 Wrong drive type?
10454 Sector buffer test error
10455, 10456 Controller error
10459 Drive diagnostic command error
10461 Drive format error
10462 Controller seek error
10464 Hard Drive read error
10467 Drive non-fatal seek error
10468 Drive fatal seek error
10469 Drive soft error count exceeded
10470, 10471, 10472 Controller wrap error
10473 Corrupt data. Low level format might be required
10480
10481 ESDI drive D seek error
10482 Drive select acknowledgement bad
106X1
10635
10651, 10660
106XX Not listed above
107XX
109XX Check the adapter cables
112XXThis adapter does not have cache
119XX
FRU/Action
1.
Run Enhanced Diagnostics
2.
Hard Disk Drive
3.
System Board
1.
Run Enhanced Diagnostics
Information only
1.
Run Enhanced Diagnostics
1.
Run Enhanced Diagnostics
Information only
1.
Run Enhanced Diagnostics
1.
Run Enhanced Diagnostics
1.
Run Enhanced Diagnostics
1.
Run Enhanced Diagnostics
1.
Run Enhanced Diagnostics
1.
Run Enhanced Diagnostics
1.
Run Enhanced Diagnostics
Information only
1.
Hard Disk Drive (ESDI)
2.
Drive Cable
3.
System Board
1.
Run Enhanced Diagnostics
1.
Run Enhanced Diagnostics
1.
Check Configuration
2.
Ethernet Adapter
1.
Power-off computer, wait ten seconds then power-
on the computer
2.
Ethernet Adapter
1.
Check Cables
2.
Ethernet Adapter
1.
Ethernet Adapter
1.
5.25-inch External
Diskette Drive
2.
5.25-inch Diskette
Drive Adapter/A
1.
ActionMedia
Adapter/A
2.
System Board
1.
SCSI Adapter
2.
Any SCSI Device
3.
System Board
1.
3119 Adapter